Reduction of atrial defibrillation threshold with an interatrial septal electrode.

نویسندگان

  • X Zheng
  • M E Benser
  • G P Walcott
  • S D Girouard
  • D L Rollins
  • W M Smith
  • R E Ideker
چکیده

BACKGROUND The standard lead configuration for internal atrial defibrillation consists of a shock between electrodes in the right atrial appendage (RAA) and coronary sinus (CS). We tested the hypothesis that the atrial defibrillation threshold (ADFT) of this RAA-->CS configuration would be lowered with use of an additional electrode at the atrial septum (SP). METHODS AND RESULTS Sustained atrial fibrillation was induced in 8 closed-chest sheep with burst pacing and continuous pericardial infusion of acetyl-ss-methylcholine. Defibrillation electrodes were situated in the RAA, CS, pulmonary artery (PA), low right atrium (LRA), and across the SP. ADFTs of RAA-->CS and 4 other lead configurations were determined in random order by use of a multiple-reversal protocol. Biphasic waveforms of 3/1-ms duration were used for all single and sequential shocks. The ADFT delivered energies for the single-shock configurations were 1.27+/-0.67 J for RAA-->CS and 0. 86+/-0.59 J for RAA+CS-->SP; the ADFTs for the sequential-shock configurations were 0.39+/-0.18 J for RAA-->SP/CS-->SP, 1.16+/-0.72 J for CS-->SP/RAA-->SP, and 0.68+/-0.46 J for RAA-->CS/LRA-->PA. Except for CS-->SP/RAA-->SP versus RAA-->CS and RAA-->CS/LRA-->PA versus RAA+CS-->SP, the ADFT delivered energies of all of the configurations were significantly different from each other (P:<0. 05). CONCLUSIONS The ADFT of the standard RAA-->CS configuration is markedly reduced with an additional electrode at the atrial SP.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Right atrial septal electrode for reducing the atrial defibrillation threshold.

BACKGROUND The atrial defibrillation threshold (ADFT) energy of the standard lead configuration, right atrial appendage (RAA) to coronary sinus (CS), was reduced by >50% with the addition of a third electrode traversing the atrial septum in a previous study. This study determined whether the ADFT would be lowered by a more clinically practical third electrode placed in the right atrium along th...

متن کامل

Implantable atrial defibrillator with a single-pass dual-electrode lead.

OBJECTIVES We examined the feasibility and efficacy of using a single-pass, dual-electrode (Solo) lead for atrial fibrillation (AF) detection and defibrillation. BACKGROUND The efficacy and safety of an implantable atrial defibrillator (IAD) has been extensively studied; however, separate right atrial (RA) and coronary sinus (CS) defibrillation leads are used for the present system. METHODS...

متن کامل

Marked reduction in atrial defibrillation thresholds with repeated internal cardioversion.

OBJECTIVES This study was performed to assess the atrial defibrillation threshold in patients with recurrent atrial fibrillation (AF) using repeated internal cardioversion. BACKGROUND Previous studies in patients with chronic AF undergoing internal cardioversion have shown this method to be effective and safe. However, current energy requirements might preclude patients with longer-lasting AF...

متن کامل

Comparison of the defibrillation threshold and the upper limit of ventricular vulnerability.

To examine the relationship between the defibrillation threshold and the strength of shocks that induce ventricular fibrillation during the vulnerable period, we determined the defibrillation threshold in 22 open-chest dogs using epicardial defibrillation electrodes with the cathode at the ventricular apex and the anode at the right atrium. We also determined whether there was an upper limit of...

متن کامل

Atrial defibrillation with a transvenous lead: a randomized comparison of active can shocking pathways.

OBJECTIVES The purpose of this study was to compare transvenous atrial defibrillation thresholds with lead configurations consisting of an active left pectoral electrode and either single or dual transvenous coils. BACKGROUND Low atrial defibrillation thresholds are achieved using complex lead systems including coils in the coronary sinus. However, the efficacy of more simple ventricular defi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 102 21  شماره 

صفحات  -

تاریخ انتشار 2000