Using Ventilation Control Technology to Reduce Respirable Dust Exposures at U.S. Metal/Nonmetal Mining Operations
ثبت نشده
چکیده
It has long been known that ventilation is a costeffective method to lower respirable dust concentrations in all types of mining applications. The National Institute for Occupational Safety and Health has been working on a number of different research techniques that use ventilation as a critical component to lower respirable dust levels at surface and metal/nonmetal operations in the United States. This article presents five such research efforts. The first research area discusses how improving the ventilation flow patterns in an iron ore mill facility lowered respirable dust concentrations by 31 pct throughout the primary grinding area. The second research area examines how respirable dust levels were lowered at a dimensional stone shop by using air cleaning units suspended from the ceiling. A third area discusses how improvements in ventilation at underground limestone mines lowered respirable dust concentrations. The fourth area examines how improvements in dust filtration and pressurization systems significantly impacted the air quality in enclosed cabs of surface mining equipment. The last area presents a newly developed clothes cleaning technique. This technique uses an air spray manifold to blow dust from a worker’s clothing in an enclosed booth, which confines the dust for capture and removal by a baghouse dust collector. These research areas represent an array of different control technologies to lower respirable dust concentrations. Ventilation is an integral part of these control technologies.
منابع مشابه
Study to Assess Respirable Dust Exposures in Underground U.S. Coal Mines
In 1991 the Mine Safety and Health Administration conducted a special program to assess occupational exposures to respirable coal mine dust in underground coal mines. Priority was given to longwall mining operations, mines with a history ofhaving a problem controlling dust to the applicable standard, and a representative number of all other mines. Measurements were obtained on approximately 720...
متن کاملEvaluation of dust exposure to truck drivers following the lead haul truck
Haul trucks have the potential to generate large amounts of respirable dust. This respirable dust has been shown to be a health hazard to personnel, especially if it has a high silica content. Lack of dust sampling data from haul trucks prompted the completion of a study to quantify respirable dust concentrations. These field studies were conducted measuring instantaneous respirable dust at sta...
متن کاملControlling respirable dust in underground coal mines in the United States
As mining operations in the United States (US) have become more productive, con trolling the dust exposure of mine workers has become more challenging. In response, US mining operations are applying basic controls at elevated levels and are looking to emerging control tech nologies in an effort to better control airborne respirable dust levels. The Pittsburgh Research Laboratory (PRL) of the ...
متن کاملOccupational and biological monitoring of workers exposed to airborne dust in Gol-e-Gohar Iron Ore mine: A Case-Control Study
Background and aims: Mining is categorized with considerable exposure to airborne contaminations. Regarding the high prevalence of diseases and the high population of workers in iron ore mines, the aim of this study was to investigate the effect of miners’ exposure to respirable dust compounds on the serum Malondialdehyde (MDA) levels. Methods: In this study, 92 non-smoker healthy workers of G...
متن کاملEfficiency of a tool-mounted local exhaust ventilation system for controlling dust exposure during metal grinding operations.
In general, control of metal dust from hand-held disk grinders is difficult because such respirable dust tends to disperse in every direction around the grinding wheel and cannot be captured effectively by a conventional exhaust hood. The author described the application of a custom-made tool-mounted local exhaust ventilation (LEV) system attached to a hand-held disk grinder, and by laboratory ...
متن کامل