AbstractID: 4975 Title: Modeling Dose Delivery Accuracy of IMRT Head-and-Neck Cancer Treatment

ثبت نشده
چکیده

ID: 4975 Title: Modeling Dose Delivery Accuracy of IMRT Head-and-Neck Cancer Treatment Purpose: To evaluate the impact of internal organ variations on IMRT treatments of head-and-neck cancers using different daily alignment techniques. Method and Materials: Eleven head-and-neck cancer patients were imaged twice weekly during their course of treatment (141 CT scans total) using an integrated CT-linear accelerator (EXaCT, Varian Oncology Systems). The clinical IMRT plans were copied onto the daily CT images. The plans were aligned with (1) the daily marked isocenter using three radio-opaque markers (BBs) and (2) bone alignment, using in-house software to align the cervical vertebrae. Daily dose distributions were mapped from the daily CT images onto the planning CT image with an in-house deformable image registration algorithm. Cumulative dose-volume histograms from the planning CT image were analyzed. Results: The differences in the clinical target volumes (CTV) gEUD between the planned and delivered doses (with BB or bone alignment) were typically ≤1Gy; therefore the differences in target coverage were most likely clinically insignificant. However, the alignment method did have a statistically significant impact on the percentage-volume of the CTV at the prescription dose. Neither BB alignment nor bone alignment maintained the planned coverage (average=98.2%), which was reduced to 95.6% with bone alignment (p=0.000) and 94.3% with BB alignment (p=0.000). BB alignment significantly increased the average percentage-volume receiving ≥25Gy above the original plan for the ipsilateral (59.6% vs. 51.4%, p=0.003) and contralateral (42.0% vs. 36.4%, p=0.016) parotid glands. The parotid gland gEUD increased by more than 5Gy in 35% of BB alignments and 15% of bone alignments. However, there was no statistically significant difference between BB and bone alignments in parotid dose received. Conclusions: The differences in CTV coverage between bone and BB alignment were statistically significant but small. Bone alignment more closely reproduced the planned parotid dose than BB alignment, although both gave higher dose than the original plan.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dose Distribution Analysis of Rapid Arc and Intensity Modulated Radiotherapy Plan in Head and Neck Cancer

Introduction: Globally, intensity-modulated radiation therapy (IMRT) is considered as highly precise and accurate method of radiotherapy planning. This technique amplifies spatial dose distribution conformity by modulating the intensity of radiation beams in each sub-volume. Additionally, it can reduces the dose to surrounding critical organs and deliver the planned dose to targets with the nom...

متن کامل

Evaluating positional accuracy using megavoltage cone-beam computed tomography for IMRT with head-and-neck cancer

Accurate dose delivery is essential for the success of intensity-modulated radiation therapy (IMRT) for patients with head-and-neck (HN) cancer. Reproducibility of IMRT dose delivery to HN regions can be critically influenced by treatment-related changes in body contours. Moreover, some set-up margins may not be adaptable to positional uncertainties of HN structures at every treatment. To obtai...

متن کامل

The effect of high energy photon beam in dose- volume parameters and integral dose of normal structures in Head and neck IMRT

Introduction: The aim of this study is to investigate the effect of partially used high photon energies on dosimetric parameters and integral doses of nasopharynx IMRT plans.   Materials and Methods: Two 7 coplanar IMRT plan were created for eleven patients (6 MV only IMRT plan in both phase1 and phase2 and 6 MV phase1-mixed energies (6 MV and 15 MV) phase2...

متن کامل

Comprehensive end-to-end test for intensity-modulated radiation therapy for nasopharyngeal carcinoma using an anthropomorphic phantom and EBT3 film

Background: In head and neck radiotherapy, immobilization devices can affect dose delivery. In this study, a comprehensive end-to-end test was developed to evaluate the accuracy of radiotherapy treatment. Materials and Methods: An Alderson Radiation Therapy (ART) anthropomorphic phantom with EBT3 film was used to mimic the actual patient treatment process. Ten patients treated for nasopharyngea...

متن کامل

An Estimation of Radiobiological Parameters for Head-and-Neck Cancer Cells and the Clinical Implications

In vitro survival measurements using two human head-and-neck cancer (HNC) cell lines were performed. The specially designed split-dose surviving fraction was obtained and fitted to the linear-quadratic formalism. The repair halftime (Tr), the potential doubling time (Td), a/β and radiosensitivity a, were estimated. Other radiobiological models: EUD, BED, TCP, etc., were used to examine the pote...