Synthetic Mesh Re-Styling of Pacemaker Ppockets
نویسنده
چکیده
Different complications after Pacemaker (PM) implantation, as skin erosion, cutaneous exposure or even extrusion of the generator device, require surgical decision, with different procedures. We describe our experience, with new pocket manufacturing beneath the pectoralis major muscle (PmM) associated to wrapping of the PM generator in a polypropylene synthetic mesh. Safe anchorage and muscular plane strengthening is then achieved.
منابع مشابه
FOA: an XSL-FO Authoring Tool
FOA [Formatting Object Authoring] is an open-source authoring tool that applies rich styling to XML content. It allows the styling to be re-used across multiple documents. It also allows the author to build or import a library of style components. It is based on XSL-FO, the W3C-defined markup language, whose aim is to add rich styling to XML content, especially for paginated documents. The arch...
متن کاملPacemaker Twiddler's Syndrome
A 76-yr-old man with unipolar ventricular pacemaker, previously implanted in the right ventricular apex, presented with syncopal attack and twitching of the right pectoralis muscle. He finally was diagnosed as having Twiddler's syndrome. The patient had a pulse rate of 36/min and cannon waves in the neck veins. Chest radiography showed a dislodged pacing lead completely wrapped around the pulse...
متن کاملBus-Styling Appraisement Research Using Extension Theory-Based on Artificial Neural Network
Automotive body styling appraisement is very important for body styling design. Because there is not tangible standard at the structure ascertaining of artificial neural network(ANN) and improvement of stability is needed for ANN inside black box characteristic, a bus-styling appraisement method using extension theory-based artificial neural network is presented. The key techniques of quasi-thr...
متن کاملTHE ROLE OF PACEMAKER CLINIC IN THE FOLLOW-UP OF PATIENTS WITH PERMANENT PACEMAKERS
The Pacemaker Clinic at Shahid Rajai Cardiovascular Research Center first started operating in August 1992. In its first year of operation, 294 permanent pacemaker patients were studied, allowing an appraisal to be carried out of the clinic's effectiveness in diagnosing and treating early complications. In the final analysis, pacemaker complications were observed in 68 (23%) patients, of wh...
متن کاملPelvic organ prolapse repair with Prolift® mesh
The long term durability of conventional surgical repair of vaginal prolapse has been questioned in recent years. In a frequently quoted publication Olsen et al.1 estimated that the lifetime risk (up to age 80 years) of undergoing surgery for vaginal prolapse was 11%. Between 29% and 40% of prolapse surgery is for recurrence 1, 2 and in 60% of re-operations the prolapse is at the site of the or...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2012