Stereotactic operations using the o-arm.

نویسندگان

  • Jani Petri Antton Katisko
  • Mikko Tapio Kauppinen
  • John Pertti Koivukangas
  • Esa Raimo Heikkinen
چکیده

BACKGROUND In stereotactic operations, intraoperative imaging is crucial in several stages of the procedure. The aim was to utilize the O-arm intraoperatively for (1) planning the trajectories of stereotactic instruments, (2) calculating the coordinates of the targets, (3) identification of normal intracranial structures, (4) verification of the trajectories of the stereotactic instruments, and (5) visualization of intracranial hematoma. This is the first study using the O-arm for calculations of the target coordinates in frame-based stereotaxy. METHODS Utilization of the O-arm as a full-scale intraoperative imaging system in stereotactic surgery required a new concept. The concept consists of the O-arm as an intraoperative imaging system and the Leksell stereotactic system with a modified CT coordinate indicator box, with the idea to widen limited imaging volume. The accuracy and feasibility of the concept were studied. RESULTS The use of O-arm imaging was found to be clinically feasible, enabling the achievement of adequate technical accuracy for stereotactic operations with submillimeter errors in the calculation of target coordinates, and for multiple intraoperative control images when required. CONCLUSIONS The O-arm could be used alone, with high accuracy, as an intraoperative imaging system for planning and controlling in stereotactic operations. In addition, it can be used to exclude serious complications, especially intracerebral hematoma.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of a prototype stereotactic collimation assembly for Neptun 10 PC linac

Background: A set of hardware stereotactic radiosurgery is designed and constructed. The scope of this article is to describe how we have designed and developed stereotactic collimation assembly for a 9 MV Neptun 10 PC linac. Materials and methods: One collimator holder and six collimators were made, with their radiation field diameter between 12.5 mm to 25 mm at isocenter level. Beam data, suc...

متن کامل

Stereotactic guidance for navigated percutaneous sacroiliac joint fusion

Arthrodesis of the sacroiliac joint (SIJ) for surgical treatment of SIJ dysfunction has regained interest among spine specialists. Current techniques described in the literature most often utilize intraoperative fluoroscopy to aid in implant placement; however, image guidance for SIJ fusion may allow for minimally invasive percutaneous instrumentation with more precise implant placement. In the...

متن کامل

Use of Frameless Stereotactic Neuronavigation and O-arm for Transoral Transpalatal Odontoidectomy to Treat a Very High Basilar Invagination

Frameless stereotactic neuronavigation system has been in wide use since many years for precise localization of cranial tumors and navigation for spinal instrumentation. We present its usage in the localization of odontoid process in a very high basilar invagination for a transoral transpalatal resection of the same. We discuss the technical aspects of assembly of neuronavigation system, O-arm ...

متن کامل

Transmitted vibrations to the wrist and arm of a chainsaw operator: The effect of wood cutting process

Introduction: Due to the non-developed mechanization situation, chainsaw is a widely used tool in Iranian forests. This tool can trigger unwelcome disorders (e.g., white finger syndrome) due to the transmitted vibrations from its handle to the body members. Characterizing these vibrations can result in minimizing the intensity of these disorders. This study aims to investigate the effect of dif...

متن کامل

Sacral nerve stimulation lead implantation using the o-arm

BACKGROUND Sacral neuromodulation operations have usually been performed based on 2D fluoro images. However, sacral nerve stimulation lead implantation may be challenging when the normal anatomy is confused by obesity or congenital anomalies. Thus the surgical navigation and intraoperative imaging methods could be helpful as those same methods have proven to be feasible methods for guiding othe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stereotactic and functional neurosurgery

دوره 90 6  شماره 

صفحات  -

تاریخ انتشار 2012