Effect of solvent and initial water content on (R, S)-1-phenylethanol resolution
نویسندگان
چکیده
The enzymatic resolution of (R, S)-1-phenylethanol was carried out in various organic solvents. Two commercial immobilized lipases, such as ChiroCLEC-PC and Chirazyme L2, c.f., C3, lyo used in this study could exhibit the highest performance in isooctane. The effects of initial water content on the activity and enantioselectivity of the enzymes were also investigated. The method of direct contact pre-equilibrium, such as substrate pre-equilibrium and enzyme pre-equilibrium were used in this study. The resolution was favourable in the absence of additional water and water mimicking compound such as glycerol in the reaction system. The enantioselectivity of the enzymes was not a ( ©
منابع مشابه
Determination of 2-phenylethanol in Rose Water Using Dispersive Liquid-Liquid Microextraction with Gas Chromatography Flame Ionization Detection
A simple and rapid microextraction procedure based on dispersive liquid-liquid microextraction (DLLME) coupled with gas chromatography-flame ionization detection (GC-FID) was developed for the extraction and analysis of 2-phenylethanol in rose water sample. In the proposed approach, carbon tetrachloride and ethanol were used as extraction and dispersive solvents, respectively. Some important pa...
متن کاملSolvent control of optical resolution of 2-amino-1-phenylethanol using dehydroabietic acid.
The optical resolution of 2-amino-1-phenylethanol (2-APE) by the solvent switch method was investigated using dehydroabietic acid (DAA), a natural chiral acid obtained as one of the main components of disproportionated rosin. The solvent dependency of optical rotation measurements of 2-APE, DAA and the diastereomeric salts suggested solvent control of optical resolution. Both (R)- and (S)-2-APE...
متن کاملDetermination of 2-phenylethanol in Rose Water Using Dispersive Liquid-Liquid Microextraction with Gas Chromatography Flame Ionization Detection
A simple and rapid microextraction procedure based on dispersive liquid-liquid microextraction (DLLME) coupled with gas chromatography-flame ionization detection (GC-FID) was developed for the extraction and analysis of 2-phenylethanol in rose water sample. In the proposed approach, carbon tetrachloride and ethanol were used as extraction and dispersive solvents, respectively. Some important pa...
متن کاملCombinatorial Library Based Engineering of Candida antarctica Lipase A for Enantioselective Transacylation of sec-Alcohols in Organic Solvent**
A method for determining lipase enantioselectivity in the transacylation of sec-alcohols in organic solvent was developed. The method was applied to a model library of Candida antarctica lipase A (CalA) variants for improved enantioselectivity (E values) in the kinetic resolution of 1-phenylethanol in isooctane. A focused combinatorial gene library simultaneously targeting seven positions in th...
متن کاملPreparation of Polyvinylchloride Nanofiltration Membrane: Investigation the Effect of Thickness, Prior Evaporation Time and Addition Polyethylenglchol as Additive on Membrane Performance and Properties
In this work, polyvinylchloride (PVC) membrane prepared via casting solution technique and phase inversion method. N, N dimethylacetamide (DMAC) was used as primary solvent and Tetrahydrofuran (THF) was used as a co-solvent. The effects of parameters such as membrane thickness, evaporation time of casting film before immersion precipitation and addition of polyethylenglchol (PEG) on PVC membran...
متن کامل