Intermediate-term durability of bicuspid aortic valve repair for prolapsing leaflet.
نویسندگان
چکیده
OBJECTIVE To determine the durability of repair of a bicuspid aortic valve with leaflet prolapse, and to identify factors associated with repair failure. METHODS From November 1988 to January 1997, 94 patients with a bicuspid aortic valve and regurgitation from leaflet prolapse had aortic valve repair. In 66 patients, the repair employed triangular resection of the prolapsing leaflet. The remainder underwent mid-leaflet plication of the prolapsing leaflet. Mean age was 38 +/- 10 years and 93% were male. Median follow-up was 5.5 years (range 0.2-9 years). Factors associated with aortic valve competence and durability were identified by multivariable logistic and hazard function analyses. RESULTS Early valve competence was more difficult to achieve in patients with large, poor functioning ventricles (P = 0.02). Aortic valve reoperation was necessary in 12 patients that included three re-repairs and nine aortic valve replacements. Freedom from reoperation was 95, 87 and 84% at 1, 5 and 7 years, respectively. The instantaneous risk of reoperation was highest immediately after operation, and fell rapidly to approximately 2% per year and less after 2 years. The only risk factor identified was the presence of residual aortic regurgitation (trace to mild in 35 cases) on immediate intraoperative post-repair transesophageal echocardiography. Late aortic regurgitation did not progress detectably across time (P = 0.3). There were no deaths, early or late. CONCLUSION Bicuspid aortic valve repair for prolapsing leaflet is a safe procedure with good intermediate-term outcome. However, any residual aortic regurgitation jeopardizes repair durability and initial repair achievement is more difficult in patients with dilated, poor functioning ventricles.
منابع مشابه
Pericardial patch augmentation for repair of incompetent bicuspid aortic valves at midterm.
OBJECTIVE Reoperation rates after repair of bicuspid aortic valves are higher than for mitral valve reconstruction. Satisfactory results have been reported for patch augmentation for tricuspid aortic valves. We have applied this technique for the repair of bicuspid aortic valves. METHODS Autologous pericardium is sutured to the free edge of the prolapsing bicuspid leaflet. A large coaptation ...
متن کاملValve-preserving surgery on the bicuspid aortic valve.
Valve repair has emerged as an important intervention for the management of bicuspid aortic valve disease. This systematic review aims to assess the safety, efficacy and durability of bicuspid aortic valve repair. Initial searches yielded 682 abstracts, reduced by de-duplication to 370, of which 56 full papers were accessed and 30 met the inclusion criteria. Overall, 163 unique outcomes for bic...
متن کاملBicuspid Aortic Valve: An Unusual Cause of Aneurysm of Left Coronary Sinus of Valsalva
Bicuspid aortic valve is traditionally considered an innocuous congenital anomaly. Due to a better and widespread availability of non-invasive imaging techniques, it has come to the fore that 30% of these cases develop complications, viz., valve abnormality (aortic regurgitation and stenosis), and aneurysm of aortic root and ascending aorta. Sinus of Valsalva aneurysm is an uncommon complicatio...
متن کاملeComment. David operation for aortic root surgery in Marfan patients: neo-sinuses and neo-sinotubular junction or not?
Noirhomme P et al. Valve sparing-root replacement with the reimplanta-tion technique to increase the durability of bicuspid aortic valve repair. David valve-sparing aortic root replacement: equivalent mid-term outcome for different valve types with or without connective tissue disorder. RS et al. Results of matching valve and root repair to aortic valve and root pathology. Repair of the bicuspi...
متن کاملAortic Valve Repair for Adult Congenital Heart Disease
Background—Aortic valve–preserving procedures have resulted in excellent outcomes in selected patients, particularly those with normal aortic valve leaflets and dilated aortic roots. However, several congenital heart lesions are associated with abnormal aortic valve leaflets. The long-term results of aortic valve repair for these lesions are not well defined. Methods and Results—We reviewed the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
دوره 15 3 شماره
صفحات -
تاریخ انتشار 1999