The Interference Free Determination of Selenium in Environmental and Clinical Samples

نویسنده

  • Justine Clare Turner
چکیده

The Interference Free Determination of Selenium in Environmental and Clinical Samples by ICP-MS Justine Clare Turner The determination of selenium in environmental and clinical samples by ICP-MS is complicated by both poor sensitivity and severe interferences resulting from both the sample matrix and the argon plasma. The purpose of this study was to investigate ways of overcoming these problems thus enabling Se to be determined both accurately and precisely. A novel procedure for the accurate determination of selenium in serum using electrothermal vaporisation inductively coupled plasma mass spectrometry (ETV-ICP-MS) has been developed. A simple I :20 dilution of the serum with 1% nitric acid negates the need for a lengthy sample digestion procedure. Several of the interferences normally associated with the analysis of selenium by ICP-MS are successfully eliminated. Analytical method characteristics include; detection limits of approximately O.lng g" 1 for Se and Se, short and lonf: term reproducibility between 4.7% and 4.9%, and 3.2% and 3.8% (RSD) for Se and Se respectively, and accuracy of ±1.81% (Se) and± 1.10% (Se) for the certified reference material NIST SRM I598. Further development of the procedure involved the application of isotope dilution analysis with the measurement of the Se/Se isotope ratio, following spiking with selenium enriched in Se. Accuracy (±0-2%) and precision (±I-3%) of the method is demonstrated with the analysis of several certified reference materials (TMRAIN-95, LGC 60 I 0, TMDA-54.2 and NIST I598) where all results fell within the certified limits. A comparison of the new ETV procedures with established ICP-MS methods involving hydride generation and the use of organic solvents with pneumatic nebulisation was performed. Full uncertainty estimates for each of the procedures investigated were calculated. The uncertainty estimates calculated highlight the improvements in accuracy and precision achievable with isotope dilution analysis, demonstrated by a 2.5 fold improvement in the uncertainty compared with the non-IDMS ETV procedure. The addition of nitrogen and helium to the different Ar gas streams of the ETV -ICP-MS system was performed. The introduction of both nitrogen and helium to the argon nebuliser and outer gas streams, resulted in a reduction in the interference from argon polyatomic species. Careful optimisation of plasma parameters such as RF power and gas flow rates using a plasma containing 50% helium in the argon outer gas stream, successfully gave rise to a 2-fold improvement in the detection limits for Se and Se compared with an argon only plasma. This study has resulted in the successful development of a high accuracy procedure to determine selenium in both environmental and clinical samples. This is of great importance considering the high level of interest regarding selenium and human health matters and the significance of accurate analytical data.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Facile Catalytic- Kinetic Method for The Determination of Selenium (IV)

A catalytic-kinetic method for the determination of selenium is proposed. Alizarin navy blue is reduced by sodium sulfide to from a colorless product. The reaction is accelerated by trace amounts of Se (IV), and can be followed by measuring the decrease in absorbance of the dye at 620nm and 30 °C by the fixed time method. Selenium can be determined in the range of 0.004 — 0.12 1.1g.m1-1 . ...

متن کامل

Positive interference in Radioimmunoassay determination of serum total T3

Introduction: Determination of thyrotropin, total and free thyroxine and triiodothyronine are widely used as diagnostic methods for thyroid function evaluation. There have been numerous reports of interferences in thyroid hormone immunoassays. Herein, a prominent positive interference is reported for a radioimmunoassay kit of total triiodothyronine. Materials and Methods: In this study, a total...

متن کامل

Interference-free Determination of Carbamazepine in Human Serum Using High Performance Liquid Chromatography: A Comprehensive Research with Three-way Calibration Methods

In the present study, a comprehensive and systematic strategy was described to evaluate the performance of several three-way calibration methods on a bio-analytical problem. Parallel factor analysis (PARAFAC), alternating trilinear decomposition (ATLD), self-weighted alternating trilinear decomposition (SWATLD), alternating penalty trilinear decomposition (APTLD) and unfolded partial least squa...

متن کامل

Determination of Selenium(IV) Using o-Phenylenediamine by Differential Pulse Polarography/Interference of Metal Ions

Determination of selenium in biological and environmental samples is usually difficult due to its trace or ultra-trace quantities, pre-concentration stages, destruction of organic matrices by acid digestion and oxygen plasma combustion followed by separation from interfering metal ions such as ion exchange separation, solvent extraction or hydride generation. Selective separation of selenium is...

متن کامل

Interference-free Determination of Carbamazepine in Human Serum Using High Performance Liquid Chromatography: A Comprehensive Research with Three-way Calibration Methods

In the present study, a comprehensive and systematic strategy was described to evaluate the performance of several three-way calibration methods on a bio-analytical problem. Parallel factor analysis (PARAFAC), alternating trilinear decomposition (ATLD), self-weighted alternating trilinear decomposition (SWATLD), alternating penalty trilinear decomposition (APTLD) and unfolded partial least squa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013