PUBLICATION III Submillimeter-wave kinetic inductance bolometers on free-standing nanomembranes

نویسندگان

  • Andrey V Timofeev
  • Visa Vesterinen
  • Panu Helistö
  • Leif Grönberg
  • Juha Hassel
  • Arttu Luukanen
چکیده

We introduce a microwave submillimeter-wave detector based on an integrated micromesh absorber and superconducting kinetic inductance thermometer on a through-wafer released sub-micron thick membrane. Equilibrium operation achieved by thermal isolation through the membrane geometry enables operation at elevated thermal bath temperatures of 5–10 K. The bolometer operates in a phonon-noise limited regime with a measured noise equivalent temperature difference of below 10 mK at 1 s integration time, which is sufficient for radiometric imaging in terrestrial systems. We also measured and analyzed the bolometer frequency response in the band 0.1–1.4 THz. Performance improvements through further dimensional scale-down and temperature dependency are discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Superconducting Microstrip-Fed Antenna Coupled to a Microwave Kinetic Inductance Detector

A proper antenna to couple to a microstrip Microwave Kinetic Inductance Detector (MKID) is designed and simulated. A twin-slot microstrip-fed inline antenna is designed for frequency band of 600-720~GHz integrated with an elliptical lens and coupled to the MKID. A systematic design procedure for design of such antenna with microstrip inline feeding is presented. Whole structure of lens and twin...

متن کامل

CALDER: neutrinoless double-beta decay identification in TeO\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$_2$$\end{document}2 bolometers with kinetic inductance detectors

Next-generation experiments searching for neutrinoless double-beta decay must be sensitive to a Majorana neutrino mass as low as 10 meV. CUORE , an array of 988 TeO2 bolometers being commissioned at Laboratori Nazionali del Gran Sasso, features an expected sensitivity of 50– 130 meV at 90 % C.L. The background is expected to be dominated byα radioactivity, and can be in principle removed by det...

متن کامل

Microwave Kinetic Inductance Detector (MKID) Camera Testing for Submillimeter Astronomy

Developing kilopixel focal planes for incoherent submmand mm-wave detectors remains challenging due to either the large hardware overhead or the complexity of multiplexing standard detectors. Microwave kinetic inductance detectors (MKIDs) provide a efficient means to produce fully lithographic backgroimd-limited kilopixel focal planes. We are constructing an MKID-based camera for the Caltech Su...

متن کامل

The space cryogenic submillimeter telescope based on hot

Extremely sensitive detectors are necessary for deep full-sky survey of distant extragalactic sources in the submillimeter-wave region by the cryogenically cooled telescope at the International Space Station (project Submillimetron). Detection of faint sources needs wide-band continuum observation using direct detectors (bolometers) not restricted by the quantum noise of indirect heterodyne rec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015