Intratester and intertester reliability of the KT-1000 arthrometer in the assessment of posterior laxity of the knee.

نویسندگان

  • F E Huber
  • J J Irrgang
  • C Harner
  • S Lephart
چکیده

We measured tibial translation in the knees of 22 subjects with posterior cruciate ligament tears or reconstructions by using the KT-1000 arthrometer. To assess the reliability of the device, two testers made measurements. One tester was a novice and the second tester had substantial clinical experience with the KT-1000 arthrometer. The quadriceps neutral angle was found for the uninvolved knee. Anterior and posterior translation and total anterior-posterior excursion were then measured. The quadriceps neutral angle was then reproduced in the involved knee and the same measurements were taken. Each subject was tested twice by each tester. The intraclass correlation coefficient values for the novice, experienced, and intertester reliability were 0.67, 0.79, and 0.62, respectively, for corrected posterior translation; 0.59, 0.68, and 0.64, respectively, for corrected anterior translation; 0.70, 0.74, and 0.29, respectively, for quadriceps neutral angle; and 0.84, 0.83, and 0.62, respectively, for total anterior-posterior excursion. Ninety-five percent confidence intervals for the novice, experienced, and intertester reliability were +/-2.95, +/-2.53, and +/-3.27 mm, respectively, for corrected posterior translation; +/-3.99, +/-3.89, and +/-3.74 mm, respectively, for corrected anterior translation; and +/-10.70 degrees, +/-11.73 degrees, and +/-16.25 degrees, respectively, for quadriceps neutral angle. The KT-1000 arthrometer was found to be a moderately reliable tool for the measurement of tibial translation in patients with posterior cruciate ligament tears and reconstructions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Knee Laxity or Loss of Knee Range of Motion after PCL Reconstruction: A Systematic Review and Meta-Analysis

Background. PCL reconstruction is a successful method for enhancing the patientchr('39')s quality of life but posterior knee laxity and knee stiffness have still occurred surgery. There is no study to evaluate knee laxity or loss of knee range of motion after surgery. Objectives. To assess the outcomes after PCL reconstruction, we: 1) evaluated the range of motion of the knee, 2) evaluated pos...

متن کامل

Robotic knee laxity testing: reliability and normative data.

PURPOSE To evaluate the reliability of the GeNouRoB knee arthrometer and present normative values of knee anterior laxity using this device on young females. METHODS Anterior laxity in both knees was tested in two groups of young, uninjured females using the hamstrings electromyography biofeedback feature of the device. There were 13 participants in the group tested for reliability and 23 for...

متن کامل

Measurement of the tibial anterior-posterior translation for Lachman test in the awake state and under anesthesia using electromagnetic measurement system.

Introduction: Anterior cruciate ligament (ACL) deficiency causes an increase in anterior tibial translation. To assess the amount of the anterior-posterior tibial translation, KT-arthorometer has been widely used. However it has been suggested by some reports that the practical reliability of the KT-1000 arthrometer measurement is doubted due to the interand intra-examiner errors. The Lachman t...

متن کامل

Measurement of anterior-posterior knee laxity: a comparison of three techniques.

Several non-invasive techniques have been developed to assess anterior-posterior (A-P) laxity of the knee, however, their accuracy remains unclear. Roentgen Stereophotogrammetry Analysis (RSA) is a three-dimensional motion analysis method that has been shown to be an accurate tool for evaluating joint kinematics. Thus. RSA provides a means that can be used to evaluate other less invasive techni...

متن کامل

Intertester and intratester reliability of a movement control test battery for patients with knee osteoarthritis and controls

OBJECTIVES To develop a test battery of movement control (MC) tests and assess its intertester and intratester reliability. METHODS 29 subjects with knee OA with mean age of 64.7 (SD 8.7) years and 12 controls without either knee pain or previous diagnosis of OA (mean age 36.6 (SD 16.2) years) were included. Two experienced physiotherapists rated the filmed test performance of six MC tests bl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The American journal of sports medicine

دوره 25 4  شماره 

صفحات  -

تاریخ انتشار 1997