BIASES ASSOCIATED WlTH FOUR STREAM SUBSTRATE SAMPLERS

نویسندگان

  • Michael K. Young
  • Wayne A. Hubert
  • Thomas A. Wesche
چکیده

A. Wesche. 1991. Biases associated with four stream substrate samplers. We compared samples collected from 10 substrates of various compositions with a single-probe freeze-core sampler, a triple-probe freeze-core sampler, a McNeil sampler, and a shovel. The accuracy with which these devices sampled particles larger than 50 mm in diameter varied; they were oversampled by the freeze-core devices, sampled in proportion to their availability by a shovel, and sampled inconsistently by the McNeil Sam-' pler. The geometric mean particle size and variance of single-probe freeze-core samples consistently exceeded those of samples collected with the other devices. Most sample means also exceeded the test substrate means. By excluding the proportions of particles larger than 50 mm in diameter in our analyses, we found that proportions of several particles sizes in samples collected by different methods differed significantly from the actual proportions in test substrates. There were few differences between the single-and triple-probe freeze-core samples or between McNeil and shovel samples. All four samplers were biased, but the McNeil sampler most frequently produced samples that approximated the true substrate composition. Nous avons compare des echantillons preleves dans dix substrats de composition variable au moyen d'un echan-tillonneur A carottes (freeze core) 2 sonde unique, d'un 6chantillonneur A carottes (freeze core) 5 sonde triple, d'un echantillonneur McNeil et d'une pelle. La precision du prekvement d'une particule ayant un diamPtre superieur A 50 mm a varie selon les dispositifs utilises; ces particules etaient sur-representees dans les preleve-ments faits avec les carrotteurs, etaient echantillonnes en proportion de leur disponibilite avec la pelle, et etaient preleves de maniere inconsistante avec I'echantillonneur McNeil. La taille moyenne geometrique des particules contenues dans les bchantillons du carotteur A sonde unique, ainsi que la variance, etaient constamment sup&

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Scanning Electrochemical Microscopy. Application to Polymer and Thin Metal Oxide Films

Scannlng electrochemical microscopy (SECM) in the feedback mode, where the steady-state faradaic current at a mlcrodlsk electrode tip Is measured as the tip Is scanned close to a surface, was used to lnvestlgate several dlfferent polymer films on electrode surfaces: poly( vlnylterrocene), N,N’-Ms[3-(t))prop~lE4,4‘-blp~ridkdun e r n e , and Naflon containing Os(bpy);+. The tip response (Le., pos...

متن کامل

Macrobenthos of lower Zayandehrud River

To study the macrobenthos of the lower reaches of Zayandehrud River, a distance of approximately 160 km, between Birds Garden and Varzaneh Town was investigated. Hence, eight stations, based on substrate structure, were selected using Sorber and Ekman samplers and PVC tube macrobenthos of the river were collected twice each season for a full year (2003-2004). Samples were sorted out and identif...

متن کامل

Removing H2S gas from the air stream using zeolite ZSM-5 substrate impregnated with magnetite and ferric nanoparticles

Introduction: Hydrogen sulfide (H2S) is a toxic gas that has adverse effects on human health and equipment. One of the methods for eliminating of H2S gas is the use of adsorbent substrate. In this study, the effect of adding iron oxides including ferric (Fe2O3) and magnetite (Fe3O4) nanoparticles to ZSM-5 zeolite substrate was investigated on the efficiency of H2S elimination from the air strea...

متن کامل

An Investigation of Sources of Randomness Within Discrete Gaussian Sampling

This paper presents a performance and statistical analysis of random number generators and discrete Gaussian samplers implemented in software. Most Lattice-based cryptographic schemes utilise discrete Gaussian sampling and will require a quality random source. We examine a range of candidates for this purpose, including NIST DRBGs, stream ciphers and well-known PRNGs. The performance of these r...

متن کامل

Diffusive gradient in thin-films (DGT) as risk assessment and management tools in the Central Witwatersrand Goldfield, South Africa

Diffusive gradient in thin-films (DGT) technology was used to monitor bio-available metals and the tool was developed for risk-based pollution assessment and liability apportionment in the Witwatersrand Goldfields, South Africa, where there is widespread mine-related pollution. DGT technology is a passive sampling technique whereby metal species are selectively diffused from polluted water thro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002