Feasibility of intercostal high intensity focused ultrasound ablation of clinically relevant volumes under the application of beam shaping
نویسندگان
چکیده
Background/introduction Obstruction by the thoracic cage of the high intensity focused ultrasound (HIFU) beam is one of the major challenges in the ablation of abdominal lesions. Several beam shaping methods have been proposed to reduce exposure of the ribs to acoustic energy and to recover focal point intensity. The feasibility of HIFU ablation of a clinically relevant volume applying beam shaping remains however unaddressed. In this study, feasibility was evaluated based on exposure of both the ribs as well as the near-field to acoustic energy. In addition, the volumetric ablation rate was estimated to evaluate whether clinically relevant ablation speeds can be achieved.
منابع مشابه
Numerical Study for Optimizing Parameters of High-Intensity Focused Ultrasound-Induced Thermal Field during Liver Tumor Ablation: HIFU Simulator
Introduction High intensity focused ultrasound (HIFU) is considered a noninvasive and effective technique for tumor ablation. Frequency and acoustic power are the most effective parameters for temperature distribution and the extent of tissue damage. The aim of this study was to optimize the operating transducer parameters such as frequency and input power in order to acquire suitable temperatu...
متن کاملFlooded Lung Generates a Suitable Acoustic Pathway for Transthoracic Application of High Intensity Focused Ultrasound in Liver
Background: In recent years, high intensity focused ultrasound (HIFU) has gained increasing clinical interest as a non-invasive method for local therapy of liver malignancies. HIFU treatment of tumours and metastases in the liver dome is limited due to the adjacent ultrasound blocking lung. One-lung flooding (OLF) enables complete sonography of lung and adjoining organs including liver. HIFU li...
متن کاملThermal ablation of a confluent lesion in the porcine kidney with magnetic resonance guided high intensity focused ultrasound
Background/introduction Since approximately 1.6 percent of men and women will be diagnosed with kidney and renal pelvis cancer during their lifetime, there is a growing interest in non-invasive kidney sparing therapy for renal cancer. As a consequence, several patient studies investigated the feasibility of high intensity focused ultrasound (HIFU) for the thermal ablation of renal masses. The m...
متن کاملLaparoscopic High Intensity Focused Ultrasound: Application to Kidney Ablation
This work demonstrates the feasibility of using high intensity focused ultrasound (HIFU) for selective ablation of renal tissue through laparoscopic procedures. Two laparoscopic HIFU probe prototypes were developed and tested. Probe 1: It is a hand-held probe with no integrated ultrasound imaging capability. It consists of two focused rectangular HIFU piezoceramic crystals mounted on a stainles...
متن کاملBoiling histotripsy method to mechanically fractionate tissue volumes in ex vivo bovine liver using a clinical MR-guided HIFU system
Background/introduction Most current HIFU approaches to treat liver tumors rely on thermal tissue ablation. Challenges still remain that prevent widespread clinical application of this technology including long treatment times, side effects such as skin burns, attenuation and aberration by ribs, heat diffusion and perfusion. Recently, a new method named boiling histotripsy (BH) was developed at...
متن کامل