Molecular epidemiology of microbial contamination in the operating room environment: Is there a risk for infection?

نویسندگان

  • Charles E Edmiston
  • Gary R Seabrook
  • Robert A Cambria
  • Kellie R Brown
  • Brian D Lewis
  • Jay R Sommers
  • Candace J Krepel
  • Patti J Wilson
  • Sharon Sinski
  • Jonathan B Towne
چکیده

BACKGROUND Modern operating rooms are considered to be aseptic environments. The use of surgical mask, frequent air exchanges, and architectural barriers are used to reduce airborne microbial populations. Breaks in surgical technique, host contamination, or hematogenous seeding are suggested as causal factors in these infections. This study implicates contamination of the operating room air as an additional etiology of infection. METHODS To investigate the potential sources of perioperative contamination, an innovative in situ air-sampling analysis was conducted during an 18-month period involving 70 separate vascular surgical procedures. Air-sample cultures were obtained from multiple points within the operating room, ranging from 0.5 to 4 m from the surgical wound. Selected microbial clonality was determined by pulse-field gel electrophoresis. In a separate series of studies microbial nasopharyngeal shedding was evaluated under controlled environmental conditions in the presence and absence of a surgical mask. RESULTS Coagulase-negative staphylococci were recovered from 86% of air samples, 51% from within 0.5 m of the surgical wound, whereas Staphylococcus aureus was recovered from 64% of air samples, 39% within 0.5 m from the wound. Anterior nares swabs were obtained from 11 members of the vascular team, clonality was observed between 8 strains of S epidermidis, and 2 strains of S aureus were recovered from selected team members and air-samples collected throughout the operating room environment. Miscellaneous Gram-negative isolates were recovered less frequently (<33%); however, 7 isolates expressed multiple patterns of antimicrobial resistance. The traditional surgical mask demonstrated limited effectiveness at curtailing microbial shedding, especially during symptomatic periods of rhinorrhea. CONCLUSIONS Gram-positive staphylococcal isolates were frequently isolated from air samples obtained throughout the operating room, including areas adjacent to the operative field. Nasopharyngeal shedding from person participating in the operation was identified as the source of many of these airborne contaminants. Failure of the traditional surgical mask to prevent microbial shedding is likely associated with an increased risk of perioperative contamination of biomedical implants, especially in procedures lasting longer than 90 minutes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sterile Parts of Operating Gown during Lower Limb Joint Replacement Surgery

Background: The prevention of surgical site infection is one of the most concerning issues in operating rooms. Surgicalgowns are worn as one of the intraoperative strategies for infection prevention. The present study investigated whetherthe gowns remained sterile during the surgical procedure. Furthermore, this study examined which parts of the surgicalgown were more prone to...

متن کامل

Bacterial Contamination of Single- and Multiple-Dose Vials after Multiple Use and Intravenous Admixtures in Three Different Hospitals in Iran

There is possibility of microbial contamination of any single-dose vials (SDVs), multiple-dose vials (MDVs) and admixtures (ADXs) during the preparation and injection to the patients that could be resulted in bloodstream infection. The goal of this study was to investigate the microbial contamination of MDVs and SDVs after multiple use and ADXs prepared by nursing staff in the treatment room ve...

متن کامل

Bacterial Contamination of Single- and Multiple-Dose Vials after Multiple Use and Intravenous Admixtures in Three Different Hospitals in Iran

There is possibility of microbial contamination of any single-dose vials (SDVs), multiple-dose vials (MDVs) and admixtures (ADXs) during the preparation and injection to the patients that could be resulted in bloodstream infection. The goal of this study was to investigate the microbial contamination of MDVs and SDVs after multiple use and ADXs prepared by nursing staff in the treatment room ve...

متن کامل

Eyewear contamination levels in the operating room: infection risk.

We investigated eyewear contamination levels in the operating room to assess infection risk and inform protocol development. Microbial contamination after use was found in 37.7% of disposable and 94.9% of reusable eyewear pieces. After disinfection, 74.4% of reusable eyewear also cultured positive. Disposable eyewear may reduce intercase contamination risk. Reusable eyewear may carry ongoing bi...

متن کامل

Correlation between Work-Related Musculoskeletal Disorders and Medical Errors in Surgical Technologists of Mazandaran Educational Hospitals, Iran (2019)

Background: Work-related musculoskeletal disorders (WMSDs) are among the most common occupational problems facing surgical technologists in the operating room, which could be associated with high costs and a reduction in the healthcare quality. The operating room could be the source of various types of surgical errors caused by numerous invasive procedures. This study aimed to investigate the c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Surgery

دوره 138 4  شماره 

صفحات  -

تاریخ انتشار 2005