Paravalvular mitral valve leakage presenting as congestive heart failure, missed by TTE but diagnosed by TEE: a case report
نویسندگان
چکیده
BACKGROUND Diagnosis of prosthetic valve leakage by the transthoracic echocardiogram (TTE) technique is more difficult. These limitations are diminished with the use of transesophageal echocardiogram (TEE) techniques. CASE REPORT A 71 year old Caucasian male presented with symptoms and signs of congestive heart failure. Past medical history included a bio-prosthetic mitral valve replacement for severe mitral regurgitation. TTE showed possible mitral regurgitation. As the TTE did not correlate with the finding of a high E-velocity, a TEE was performed, which showed a significant paravalvular leak of moderate severity around the bio-prosthetic mitral valve. CONCLUSION There should be a high degree of suspicion to diagnose a paravalvular leak.
منابع مشابه
Assessment of Mitral Paravalvular Leakage After Mitral Valve Replacement Using Cardiac Computed Tomography: Comparison With Surgical Findings.
BACKGROUND The diagnostic performance of cardiac computed tomography (CT) for detection of paravalvular leakage (PVL) after mitral valve replacement has not been investigated in a large population. We aimed to investigate the diagnostic accuracy of CT for diagnosis of mitral PVL using surgical findings as the standard reference and to compare the diagnostic performance of CT with those of trans...
متن کاملدریچه میترال دو دهانه با تنگی شدید، یک مورد نادر
Double orifice mitral valve (DOMV) is an uncommon anomaly that was first described by Greenfield. Since then more than 200 cases have been reported. In this anomaly, mitral valve has a single fibrous annulus which opens with two openings into the left ventricle. We report a case of DOMV accompanied with severe stenosis in a 22-year old female who had complaints of moderate dyspnea. In transth...
متن کاملSevere mitral regurgitation due to mitral leaflet aneurysm diagnosed by three-dimensional transesophageal echocardiography: a case report
BACKGROUND A small mitral valve aneurysm (MVA) presenting as severe mitral regurgitation (MR) is uncommon. CASE PRESENTATION A 47-year-old man with a history of hypertension complained of exertional chest discomfort. A transthoracic echocardiogram (TTE) revealed the presence of MR and prolapse of the posterior leaflet. A 6-mm in diameter MVA, not clearly visualized by TTE, was detected on the...
متن کاملAN INNOVATIVE SURGIC AL TECHNIQUE FOR CONTINUOUS SUTURING OF PROSTHESIS IN MITR AL VALVE REPL A CEMENT
Mitral valve replacement (MVR) is usually performed in two methods of running and interrupted suturing. In running method, the suturing of the valve is usually with some traction on the annulus and also there is a risk of aortic valve injury. This study was conducted to evaluate a new technique for suturing to avoid these complications and decrease the time of cardiac arrest. One hundred an...
متن کاملA rare case of aortic sinuses of valsalva fistula to multiple cardiac chambers secondary to periannular aortic abscess formation from underlying Brucella endocarditis
The concomitant presence of abnormal connection from three aortic valsalva sinuses to cardiac chambers is a rare complication of native aortic Brucella endocarditis. This case report presents a 37-year-old Iranian female patient who had native aortic valve Brucella endocarditis complicated by periannular abscess formation and subsequent perforation to multi-cardiac chambers associated with cong...