Low sensitivity of rapid diagnostic test for influenza.

نویسندگان

  • Timothy M Uyeki
  • Ramakrishna Prasad
  • Charles Vukotich
  • Samuel Stebbins
  • Charles R Rinaldo
  • Yu-Hui Ferng
  • Stephen S Morse
  • Elaine L Larson
  • Allison E Aiello
  • Brian Davis
  • Arnold S Monto
چکیده

The QuickVue Influenza A+B Test (Quidel) was used to test nasal swab specimens obtained from persons with influenza-like illness in 3 different populations. Compared with reverse-transcriptase polymerase chain reaction, the test sensitivity was low for all populations (median, 27%; range, 19%-32%), whereas the specificity was high (median, 97%; range, 96%-99.6%).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of a rapid immunochromatographic assay for the detection of avian influenza viruses

Rapid spreading of the low pathogenic avian influenza virus (AIV) caused by the H9N2 subtype and the highly pathogenic AIV caused by H5N1 have caused serious economic losses in the poultry industries of Asia. Therefore, the early detection of AIVs is crucial for the control of the disease. In the present study, the applicability of a rapid immunochromatographic (RIC) assay, which specifically d...

متن کامل

Test Characteristics of the Anigen® Rapid AIV Ag Test (Avian Influenza Type A Rapid Antigen Test) in Ducks in Vietnam

The current study evaluated the test characteristics of a commercially available rapid antigen test (The Anigen® Rapid AIV Ag test) for Highly Pathogenic Avian Influenza (HPAI). Diagnostic specimens were collected from 175 ducks at markets and under controlled laboratory conditions in Vietnam. The relative diagnostic test sensitivity and the relative diagnostic test specificity were calculated ...

متن کامل

Rapid influenza H1N1 diagnostic test: its diagnostic property

To the editor: The report on assessment of diagnostic properties of rapid influenza H1N1 diagnostic test demonstrated an interesting finding that ‘Rapid tests have high specificity but low sensitivity and thus limited usefulness’. The metaanalysis in this work might have some problems. As different rapid influenza H1N1 diagnostic tests have different basic principles, the use of overall sensiti...

متن کامل

Detecting Influenza A (H1N1) pdm09 Virus Infection Using Immunochromatographic Assay

The recent paper entitled “Development of a specific and rapid diagnostic method for detecting influenza A (H1N1) pdm09 virus infection using immunochromatographic assay” by Ji et al [1] is very interesting. Ji et al [1] concluded that “the proposed method can be easily used for rapid and specific detection of the pdm09 infection.” To develop a new diagnostic test for detecting influenza A (H1N...

متن کامل

Diagnostic Accuracy of a Rapid Influenza Test for Pandemic Influenza A H1N1

BACKGROUND With the current influenza A H1N1 pandemic (H1N1pdm), it is extremely important that clinicians can quickly and accurately identify influenza cases. METHODOLOGY/PRINCIPAL FINDINGS To investigate the performance of the QuickVue Influenza A+B rapid test, we conducted a prospective study of the diagnostic accuracy of the QuickVue Influenza A+B test compared to real-time reverse transc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical infectious diseases : an official publication of the Infectious Diseases Society of America

دوره 48 9  شماره 

صفحات  -

تاریخ انتشار 2009