The effect of the blue light diode laser on shear-peel bond strength of orthodontic brackets with varying curing time and distance
نویسندگان
چکیده
THE EFFECT OF THE BLUE LIGHT DIODE LASER ON SHEAR-PEEL BOND STRENGTH OF ORTHODONTIC BRACKETS WITH VARYING CURING TIME AND DISTANCE Kamran Shaikh, DDS June 17,2010 Background: Light cured composite resin can be time consuming for bonding orthodontic brackets. A new Blue light diode laser may reduce curing times for composite resins. Hypothesis: The laser will achieve similar bond strengths in half the time and at greater distances as the LED. Methods: 90 extracted premolars will be bonded and cured using Laser and LED curing units at varying times, another 120 extracted premolars will be bonded and cured at varying distances. An Instron machine will be used to test shear bond strength. Results: The laser was not able to achieve similar bond strengths as the LED curing light in half of the curing time. At 5 seconds, the laser had 35% lower bond strengths but was still in the clinically acceptable range. The laser achieved similar bond strengths when the curing tip was at greater distances as when it was close to the bracket-adhesive-tooth interface.
منابع مشابه
Effect of Saliva Contamination and sequencing time of curing the Transbond™ Plus Self Etching Primer on the Shear Bond Strength of Orthodontic Brackets
Abstract Background and aim: Over the years, improvments have been done to simplify clinical bonding procedure. One of these material is Transbond™ Plus Self Etching. The aim of this study was to evaluate the effect of saliva contamination and reusing Transbond™ Plus Self Etching Primer (SEP) on shear bond strength of orthodontic brackets. Materials and Methods: Fifty premolars divided into fiv...
متن کاملIn vitro Effects of a Neutral Fluoride Agent on Shear Bond Strength and Microleakage of Orthodontic Brackets
Introduction: This study aimed to evaluate the effect of pretreatment with a neutral fluoride agent on shear bond strength (SBS) and microleakage of orthodontic brackets, and to investigate any significant relationship between SBS and microleakage. Methods: Forty intact premolars were selected and randomly divided into 2 groups. Group 1 served as the control, while group 2 underwent treatment w...
متن کاملComparison of shear bond strength of stainless steel brackets bonded with three light- cured adhesives
Introduction: The bonding process of the brackets to enamel has been a critical issue in orthodontic research. The purpose of this study was to evaluate the shear bond strength of 3 light-cured adhesives (transbond XT, Z250, light bond). Materials &Methods: In this study sixty extracted human premolars were collected and randomly divided into 3 test groups. All teeth were etched by 37% phosp...
متن کاملShear Bond Strength of Metallic and Ceramic Brackets Bonded with Two-step and Three-step Light Cure Adhesives
Background and purpose: The bonding process is highly important in orthodontic treatment for its fast speed. The purpose of this study was to compare the shear bond strength of ceramic and metallic brackets between three stage (transbondTM XT) and two stage (GC ortho connectTM) light cure composites. Materials and methods: In this experimental study, 80 maxillary and mandibular first and sec...
متن کاملEffect of bonding protocol on shear bond strength of orthodontic brackets: An in vitro study
The aim of this study was to evaluate the shear bond strength of bracket composites as a function of the application of flow adhesive prior to the composite and light curing time. Material and methods: Freshly extracted bovine permanent central incisors (50) were acid etched and divided into four groups varying the attachment protocol: (1) no adhesive, composite light-cured for 20s; (2) no adhe...
متن کامل