Video methods for evaluating physiologic monitor alarms and alarm responses.

نویسندگان

  • Christopher P Bonafide
  • Miriam Zander
  • Christian Sarkis Graham
  • Christine M Weirich Paine
  • Whitney Rock
  • Andrew Rich
  • Kathryn E Roberts
  • Margaret Fortino
  • Vinay M Nadkarni
  • Richard Lin
  • Ron Keren
چکیده

False physiologic monitor alarms are extremely common in the hospital environment. High false alarm rates have the potential to lead to alarm fatigue, leading nurses to delay their responses to alarms, ignore alarms, or disable them entirely. Recent evidence from the U.S. Food and Drug Administration (FDA) and The Joint Commission has demonstrated a link between alarm fatigue and patient deaths. Yet, very little scientific effort has focused on the rigorous quantitative measurement of alarms and responses in the hospital setting. We developed a system using multiple temporarily mounted, minimally obtrusive video cameras in hospitalized patients' rooms to characterize physiologic monitor alarms and nurse responses as a proxy for alarm fatigue. This allowed us to efficiently categorize each alarm's cause, technical validity, actionable characteristics, and determine the nurse's response time. We describe and illustrate the methods we used to acquire the video, synchronize and process the video, manage the large digital files, integrate the video with data from the physiologic monitor alarm network, archive the video to secure servers, and perform expert review and annotation using alarm "bookmarks." We discuss the technical and logistical challenges we encountered, including the root causes of hardware failures as well as issues with consent, confidentiality, protection of the video from litigation, and Hawthorne-like effects. The description of this video method may be useful to multidisciplinary teams interested in evaluating physiologic monitor alarms and alarm responses to better characterize alarm fatigue and other patient safety issues in clinical settings.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Insights into the Problem of Alarm Fatigue with Physiologic Monitor Devices: A Comprehensive Observational Study of Consecutive Intensive Care Unit Patients

PURPOSE Physiologic monitors are plagued with alarms that create a cacophony of sounds and visual alerts causing "alarm fatigue" which creates an unsafe patient environment because a life-threatening event may be missed in this milieu of sensory overload. Using a state-of-the-art technology acquisition infrastructure, all monitor data including 7 ECG leads, all pressure, SpO(2), and respiration...

متن کامل

Anaesthesia monitor alarms: a theory-driven approach.

UNLABELLED The development of physiologic monitors has contributed to the decline in morbidity and mortality in patients undergoing anaesthesia. Diverse factors (physiologic, technical, historical and medico-legal) create challenges for monitor alarm designers. Indeed, a growing body of literature suggests that alarms function sub-optimally in supporting the human operator. Despite existing tec...

متن کامل

Association between exposure to nonactionable physiologic monitor alarms and response time in a children's hospital.

BACKGROUND Alarm fatigue is reported to be a major threat to patient safety, yet little empirical data support its existence in the hospital. OBJECTIVE To determine if nurses exposed to high rates of nonactionable physiologic monitor alarms respond more slowly to subsequent alarms that could represent life-threatening conditions. DESIGN Observational study using video. SETTING Freestandin...

متن کامل

Monitor alarm fatigue: standardizing use of physiological monitors and decreasing nuisance alarms.

BACKGROUND Reliance on physiological monitors to continuously "watch" patients and to alert the nurse when a serious rhythm problem occurs is standard practice on monitored units. Alarms are intended to alert clinicians to deviations from a predetermined "normal" status. However, alarm fatigue may occur when the sheer number of monitor alarms overwhelms clinicians, possibly leading to alarms be...

متن کامل

3 Noise - robustness of cortical responses to natural sounds increases from primary to non - primary auditory cortex

Alarms in the ICU sound frequently and 85-99% of cases do not require clinical intervention. As alarm frequency increases, clinicians develop ‘alarm fatigue’ resulting in desensitization, missed alarms, and delayed responses. This is dangerous for the patient when an alarm-provoking event requires clinical intervention but is inadvertently missed. Alarm fatigue can also cause clinicians to: set...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biomedical instrumentation & technology

دوره 48 3  شماره 

صفحات  -

تاریخ انتشار 2014