Normalization of visual evoked potentials using underlying electroencephalogram levels improves amplitude reproducibility in rats.
نویسندگان
چکیده
PURPOSE The visual evoked potential (VEP) is a frequently used noninvasive measurement of visual function. However, high-amplitude variability has limited its potential for evaluating axonal damage in both laboratory and clinical research. This study was conducted to improve the reliability of VEP amplitude measurement in rats by using electroencephalogram (EEG)-based signal correction. METHODS VEPs of Sprague-Dawley rats were recorded on three separate days within 2 weeks. The original VEP traces were normalized by EEG power spectrum, which was evaluated by Fourier transform. A comparison of intersession reproducibility and intersubject variability was made between the original and corrected signals. RESULTS Corrected VEPs showed lower amplitude intersession within-subject SD (Sw), coefficient of variation (CoV), and repeatability (R(95)) than the original signals (P < 0.001). The intraclass correlation coefficient (ICC) of the corrected traces (0.90) was also better than the original potentials (0.82). For intersubject variability, the EEG-based normalization improved the CoV from 44.64% to 30.26%. A linear correlation was observed between the EEG level and the VEP amplitude (r = 0.71, P < 0.0001). CONCLUSIONS Underlying EEG signals should be considered in measuring the VEP amplitude. In this study, a useful technique was developed for VEP data processing that could also be used for other cortical evoked potential recordings and for clinical VEP interpretation in humans.
منابع مشابه
Effects of visual deprivation on epileptic activity in mature rat visual cortex
Effects of visual deprivation on the induction of epileptiform activity were studied in layer II/III of mature rat primary visual cortex. Field potentials were evoked by stimulation of layer IV in slices from control and dark-reared (OR) rats. Picrotoxin (PTX)-induced epileptic activity was characterized by spontaneous and evoked epileptic field potentials (EFPs). The results showed that OR s...
متن کاملFeature Extraction of Visual Evoked Potentials Using Wavelet Transform and Singular Value Decomposition
Introduction: Brain visual evoked potential (VEP) signals are commonly known to be accompanied by high levels of background noise typically from the spontaneous background brain activity of electroencephalography (EEG) signals. Material and Methods: A model based on dyadic filter bank, discrete wavelet transform (DWT), and singular value decomposition (SVD) was developed to analyze the raw data...
متن کاملMachine learning based Visual Evoked Potential (VEP) Signals Recognition
Introduction: Visual evoked potentials contain certain diagnostic information which have proved to be of importance in the visual systems functional integrity. Due to substantial decrease of amplitude in extra macular stimulation in commonly used pattern VEPs, differentiating normal and abnormal signals can prove to be quite an obstacle. Due to developments of use of machine l...
متن کاملAssessing the Effect of Opium Dependence on Visual Evoked Potential (VEP) in Men
Abstract Background: Opium-dependence having different effects on the nervous system is a common problem, especially in the Middle East and Iran. The aim of this study is evaluating the effects of opium-dependence on visual evoked potential (VEP) in men. Methods: Thirty subjects with both chronic cigarette smoking and opium-dependence (group 1) and 30 subjects with only chronic ciga...
متن کاملComparison of the Wave Amplitude of Visually Evoked Potential in Amblyopic Eyes between Patients with Esotropia and Anisometropia and a Normal Group
Background: We compared the wave amplitude of visually evoked potential (VEP) between patients with esotropic and anisometropic amblyopic eyes and a normal group.Methods: The wave amplitude of VEP was documented in 2 groups of persons with amblyopia (15 with esotropia and 28 with anisometropia) and 1 group of individuals with normal visual acuity (n, 15). The amplitude of P100 was recorded mono...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 53 3 شماره
صفحات -
تاریخ انتشار 2012