Association of common carotid artery Doppler-determined dicrotic notch velocity with the left ventricular ejection fraction.

نویسندگان

  • Joseph F Polak
  • Jean M Alessi-Chinetti
  • Ayan R Patel
  • James M Estes
چکیده

OBJECTIVES The appearance of the dicrotic notch on blood pressure tracings is associated with impaired cardiac function. Common carotid artery waveforms have similar fiduciary markers, yet they have not been related to cardiac function. We studied associations of common carotid artery dicrotic notch velocities with the left ventricular ejection fraction (LVEF) determined by echocardiography. METHODS We conducted a retrospective study of 37 patients who had cardiac echocardiography and carotid Doppler evaluations within 1 day of each other. The LVEF was determined by the biplane modified Simpson rule. Doppler parameters were measured from tracings of the left common carotid artery 4 cm from the flow divider. Linear regression and stepwise multivariable linear regression models were used to evaluate any association between the LVEF and the following variables: age, sex, peak systolic velocity (PSV), end-diastolic velocity (EDV), dicrotic notch velocity, rise time (EDV to PSV), resistive index, and cardiac cycle length. RESULTS The dicrotic notch velocity was the only variable associated with the LVEF (P = .028) in a bivariate analyses. A backward selection stepwise multivariable equation predicting the LVEF had the dicrotic notch (P = .001) and resistive index (P = .01) as significant predictors, whereas the cardiac cycle length (P = .08) and PSV (P = .08) were borderline not significant. Model goodness of fit was R(2) = 0.37 (P = .004). CONCLUSIONS Dicrotic notch velocities measured from common carotid artery Doppler waveforms are associated with the LVEF and might offer some clinical value in selected cases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Deflation Timing Influences Intra-Aortic Balloon Pump-Mediated Carotid Blood Flow Reversal: A Case Report.

The patient is a 63-year-old man with stage D heart failure and a left ventricular ejection fraction of <20% who presented to the Houston Methodist Hospital with cardiogenic shock. As a part of his care, he underwent placement of an intra-aortic balloon pump (IABP). The IABP settings were for the balloon to inflate with the aortic dicrotic notch and to deflate near the end of diastole. After as...

متن کامل

Measuring the Nitroglycerine-Induced Vasodilation in Carotid Arteries

Introduction: Nitroglycerin is a fast-acting drug that rapidly dilates coronary arteries and thus increases blood flow to these vessels, and increases the blood flow through the lateral vessels to low blood areas. It also reduces both end diastolic pressure and volume of the left ventricular. However, the effect of nitroglycerin on the circulation hemodynamic is not known. Caro...

متن کامل

Doppler-Derived Myocardial Performance Index in Healthy Children in Shiraz

Background: Assessment of myocardial function is essential in heart disease, but in regard to systolic and diastolic functions such evaluation has limitation. Ejection fraction is difficult to assess in abnormally-shaped ventricles, and diastolic inflow velocity pattern may be fused because of tachycardia. Objective: A myocardial performance index (MPI) or Tei index has been developed for adult...

متن کامل

The effect of eight weeks of moderate-intensity endurance training on myocardial capillary density, ejection fraction and left ventricular shortening fraction in male rats with myocardial infarction

Background and objective: Vascular obstruction and impaired blood flow and oxygen delivery cause a myocardial infarction and limit a personchr('39')s function. Therefore, finding a way to create new arteries and replace blocked arteries has always been of interest to researchers, including exercise physiologists. Therefore, this study was conducted to evaluate the effect of eight weeks of moder...

متن کامل

Prediction of Changes in Left Ventricular Ejection Fraction after Off-Pump Coronary Artery Bypass Grafting Surgery by Myocardial Perfusion Single-Photon Emission Computed Tomography

Introduction: Left ventricular ejection fraction (LVEF) is considered to be the single most important prognostic factor in patients with previous myocardial infarction. LVEF is not improved in all patients after coronary artery bypass grafting (CABG). This study aimed to assess the possibility of prediction of LVEF changes after CABG using myocardial perfusion gated signle photon emission compu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine

دوره 34 3  شماره 

صفحات  -

تاریخ انتشار 2015