The effects of noise reduction, sharpening, enhancement, and image magnification on diagnostic accuracy of a photostimulable phosphor system in the detection of non-cavitated approximal dental caries

نویسندگان

  • Zahra Dalili Kajan
  • Reza Tayefeh Davalloo
  • Mayam Tavangar
  • Fatemeh Valizade
چکیده

PURPOSE Contrast, sharpness, enhancement, and density can be changed in digital systems. The important question is to what extent the changes in these variables affect the accuracy of caries detection. MATERIALS AND METHODS Forty eight extracted human posterior teeth with healthy or proximal caries surfaces were imaged using a photostimulable phosphor (PSP) sensor. All original images were processed using a six-step method: (1) applying "Sharpening 2" and "Noise Reduction" processing options to the original images; (2) applying the "Magnification 1:3" option to the image obtained in the first step; (3) enhancing the original images by using the "Diagonal/" option; (4) reviewing the changes brought about by the third step of image processing and then, applying "Magnification 1:3"; (5) applying "Sharpening UM" to the original images; and (6) analyzing the changes brought about by the fifth step of image processing, and finally, applying "Magnification 1:3." Three observers evaluated the images. The tooth sections were evaluated histologically as the gold standard. The diagnostic accuracy of the observers was compared using a chi-squared test. RESULTS The accuracy levels irrespective of the image processing method ranged from weak (18.8%) to intermediate (54.2%), but the highest accuracy was achieved at the sixth image processing step. The overall diagnostic accuracy level showed a statistically significant difference (p=0.0001). CONCLUSION This study shows that the application of "Sharpening UM" along with the "Magnification 1:3" processing option improved the diagnostic accuracy and the observer agreement more effectively than the other processing procedures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnosis of Approximal Caries after Delayed Scanning of Photostimulable Phosphor Plates

STATEMENT OF THE PROBLEM Considering the high diagnostic accuracy and wide dynamic range of photostimulable phosphor plates (PSPs), they can be a good alternative for radiographic films. PURPOSE This study was aimed to assess the effects of delay in scanning PSPs on the diagnostic accuracy of detection of approximal caries. MATERIALS AND METHOD Radiographs from fifty-two extracted molar and...

متن کامل

Detection of cavitated approximal surfaces using cone beam CT and intraoral receptors.

OBJECTIVES The aim of this study was to compare cone beam CT (CBCT) in a small field of view (FOV) with a solid-state sensor and a photostimulable phosphor plate system for detection of cavitated approximal surfaces. METHODS 257 non-filled approximal surfaces from human permanent premolars and molars were recorded by two intraoral digital receptors, a storage phosphor plate (Digora Optime, So...

متن کامل

Diagnostic Accuracy of Digital and Conventional Radiography in the Detection of Non-Cavitated Approximal Dental Caries

BACKGROUND Radiography plays an important role in the detection of interproximal caries. OBJECTIVES The aim of the present study was to determine diagnostic accuracy of chargecoupled devices (CCD), Photo Stimulable Phosphor (PSP) and film radiography in detecting non-cavitated caries. PATIENTS AND METHODS Seventy-two non-cavitated approximal surfaces of extracted human posterior teeth were ...

متن کامل

Diagnostic Value of Conventional and Digital Radiography for Detection of Cavitated and Non-Cavitated Proximal Caries

OBJECTIVES This study aimed to assess the diagnostic value of conventional and digital radiography for detection of cavitated and non-cavitated proximal caries. MATERIALS AND METHODS Fifty extracted human premolars and molars were mounted in a silicone block. Charge-coupled device (CCD) and photostimulable phosphor plate (PSP) receptors and intra-oral films were exposed with 60 and 70 kVp wit...

متن کامل

Comparing the Diagnostic Accuracy of Two Different Resolutions of Radiographs Captured with PSP Digital Intraoral Receptors in Detection of Secondary Caries (In Vitro)

Background and Aim: Considering the importance of detection of secondary caries, the adverse consequences of false positive and false negative diagnoses and the gap of information in the diagnostic efficacy of digital sensors in detection of secondary caries, this in vitro study sought to compare the diagnostic efficacy of two different resolutions of radiographs obtained by photostimulable pho...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 45  شماره 

صفحات  -

تاریخ انتشار 2015