Scatterer size estimation in pulse-echo ultrasound using focused sources: calibration measurements and phantom experiments.

نویسندگان

  • Timothy A Bigelow
  • William D O'Brien
چکیده

In a companion paper [T. A. Bigelow and W. D. O'Brien Jr., J. Acoust. Soc. Am. 116, 578 (2004)], theory, supported by simulations, showed that accurate scatterer size estimates could be obtained using highly focused sources provided that the derived generalized attenuation-compensation function was used and the velocity potential field near the focus could be approximated as a three-dimensional Gaussian. Herein, the theory is further evaluated via experimental studies. A calibration technique is developed to find the necessary equivalent Gaussian dimensions for a focused source using reflections obtained from a rigid plane scanned through the focus. Then, the theoretical analysis of focused sources is validated experimentally using three spherically focused ultrasound transducers to estimate the radius of glass beads imbedded in tissue mimicking phantoms. Both the impact of focusing (f/1, f/2, and f/4) and the effect of scatterer type (comparing glass bead results to simulation results that used scatterers with Gaussian impedance distributions) were tested. The simulated differences agree with the measured differences to within 2.5% provided that the comparison is made between the same scatterer type and sources with the same equivalent Gaussian dimensions. The improvement provided by the generalized attenuation-compensation function is greatly influenced by the type of scatterer whose size is being estimated and decreases as the wavelength dependence of the Gaussian depth of focus is reduced.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spatial Angular Compounding Technique for H-Scan Ultrasound Imaging.

H-Scan is a new ultrasound imaging technique that relies on matching a model of pulse-echo formation to the mathematics of a class of Gaussian-weighted Hermite polynomials. This technique may be beneficial in the measurement of relative scatterer sizes and in cancer therapy, particularly for early response to drug treatment. Because current H-scan techniques use focused ultrasound data acquisit...

متن کامل

Scatterer size estimation in pulse-echo ultrasound using focused sources: theoretical approximations and simulation analysis.

The speckle in ultrasound images has long been thought to contain information related to the tissue microstructure. Many different investigators have analyzed the frequency characteristics of the backscattered signals to estimate the scatterer acoustic concentration and size. Previous work has been mostly restricted to unfocused or weakly focused ultrasound sources, thus limiting its implementa...

متن کامل

Small field size dose-profile measurements: A comparison between Eclipse™ treatment planning system with NIPAM polymer gel dosimeter dose measurement

Introduction: Three physical conditions caused an external beam designated as a small field. The first is the loss of lateral charged particle equilibrium. The second is the effect of collimators on the primary photon source occlusion. The third condition is the size of the detector which is large compared to the field size. The most obvious perturbation effects in last condit...

متن کامل

Improved scatterer size estimation using backscatter coefficient measurements with coded excitation and pulse compression.

Scatterer size estimates from ultrasonic backscatter coefficient measurements have been used to differentiate diseased tissue from normal. A low echo signal-to-noise ratio (eSNR) leads to increased bias and variance in scatterer size estimates. One way to improve the eSNR is to use coded excitation (CE). The normalized backscatter coefficient was measured from three tissue-mimicking phantoms by...

متن کامل

Motion Compensation Algorithm for Non-invasive Two-dimensional Temperature Estimation Using Diagnostic Pulse-echo Ultrasound

The feasibility of real-time non-invasive spatio-temporal temperature estimation from pulse-echo diagnostic ultra-sound data has been previously demonstrated in stationary phantoms. The method is based on rst estimating the axial shifts of the RF-echo data due to local changes in the speed of sound and thermal expansion in the propagating medium, and then diierentiating these estimates along ax...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of the Acoustical Society of America

دوره 116 1  شماره 

صفحات  -

تاریخ انتشار 2004