Multiple inert gas elimination technique by micropore membrane inlet mass spectrometry--a comparison with reference gas chromatography.

نویسندگان

  • Moritz Kretzschmar
  • Thomas Schilling
  • Andreas Vogt
  • Hans Ulrich Rothen
  • João Batista Borges
  • Thomas Hachenberg
  • Anders Larsson
  • James E Baumgardner
  • Göran Hedenstierna
چکیده

The mismatching of alveolar ventilation and perfusion (VA/Q) is the major determinant of impaired gas exchange. The gold standard for measuring VA/Q distributions is based on measurements of the elimination and retention of infused inert gases. Conventional multiple inert gas elimination technique (MIGET) uses gas chromatography (GC) to measure the inert gas partial pressures, which requires tonometry of blood samples with a gas that can then be injected into the chromatograph. The method is laborious and requires meticulous care. A new technique based on micropore membrane inlet mass spectrometry (MMIMS) facilitates the handling of blood and gas samples and provides nearly real-time analysis. In this study we compared MIGET by GC and MMIMS in 10 piglets: 1) 3 with healthy lungs; 2) 4 with oleic acid injury; and 3) 3 with isolated left lower lobe ventilation. The different protocols ensured a large range of normal and abnormal VA/Q distributions. Eight inert gases (SF6, krypton, ethane, cyclopropane, desflurane, enflurane, diethyl ether, and acetone) were infused; six of these gases were measured with MMIMS, and six were measured with GC. We found close agreement of retention and excretion of the gases and the constructed VA/Q distributions between GC and MMIMS, and predicted PaO2 from both methods compared well with measured PaO2. VA/Q by GC produced more widely dispersed modes than MMIMS, explained in part by differences in the algorithms used to calculate VA/Q distributions. In conclusion, MMIMS enables faster measurement of VA/Q, is less demanding than GC, and produces comparable results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sequential V(A)/Q distributions in the normal rabbit by micropore membrane inlet mass spectrometry.

We developed micropore membrane inlet mass spectrometer (MMIMS) probes to rapidly measure inert-gas partial pressures in small blood samples. The mass spectrometer output was linearly related to inert-gas partial pressure (r(2) of 0.996-1.000) and was nearly independent of large variations in inert-gas solubility in liquid samples. We infused six inert gases into five pentobarbital-anesthetized...

متن کامل

A comparison of micropore membrane inlet mass spectrometry-derived pulmonary shunt measurement with Riley shunt in a porcine model.

BACKGROUND The multiple inert gas elimination technique was developed to measure shunt and the ratio of alveolar ventilation to simultaneous alveolar capillary blood flow in any part of the lung (V(A)'/Q') distributions. Micropore membrane inlet mass spectrometry (MMIMS), instead of gas chromatography, has been introduced for inert gas measurement and shunt determination in a rabbit lung model....

متن کامل

An in vitro lung model to assess true shunt fraction by multiple inert gas elimination

The Multiple Inert Gas Elimination Technique, based on Micropore Membrane Inlet Mass Spectrometry, (MMIMS-MIGET) has been designed as a rapid and direct method to assess the full range of ventilation-to-perfusion (V/Q) ratios. MMIMS-MIGET distributions have not been assessed in an experimental setup with predefined V/Q-distributions. We aimed (I) to construct a novel in vitro lung model (IVLM) ...

متن کامل

Method development in membrane inlet mass spectrometry. Air analysis and desorption techniques

Membrane inlet mass spectrometry (MIMS) is an established technique for the analysis of volatile organic compounds in aqueous solutions and in air. A thin membrane is the only interface between a liquid or gaseous sample at atmospheric pressure and the vacuum of a mass spectrometer. Since its introduction about 35 years ago MIMS has been applied mainly in biochemistry and environmental analysis...

متن کامل

High-Resolution Measurement of Volatile Organic Compounds Dissolved in Seawater Using Equilibrator Inlet-Proton Transfer Reaction-Mass Spectrometry (EI-PTR-MS)

We have developed an equilibrator inlet-proton transfer reaction-mass spectrometry (EI-PTRMS) system for the high-resolution measurement of the concentrations of multiple volatile organic compounds (VOCs) dissolved in seawater. The equilibration of six VOCs (dimethyl sulfide (DMS), isoprene, propene, acetone, acetaldehyde, and methanol) between seawater samples and the carrier gas, and the resp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 115 8  شماره 

صفحات  -

تاریخ انتشار 2013