Multimodality Imaging for Investigation of Plaque Morphology and Blood Flow: Preliminary Results

نویسندگان

  • F. T. Baluyot
  • V. Shamdasani
  • H. Underhill
  • B. Chu
  • W. S. Kerwin
  • C. Yuan
چکیده

Introduction: Complications from atherosclerosis can lead to stroke, myocardial infarction, and death. As a result, not only is the detection of atherosclerotic plaques important, an understanding of the formation and progression of lesions is vital. Furthermore, since the artery lumen is exposed to blood, the effects of blood flow, particularly wall stress, should be considered. By using different contrast weightings, MRI has shown the capability to identify plaques and various components (e.g., calcium, lipid rich necrotic core) in the carotid artery [1]. Ultrasound can also identify plaques and, to a limited extent, can identify various components based on shadowing and tissue echogenicity [2]. Both imaging modalities have the capabilities to image blood flow. Despite these imaging abilities, both techniques have limitations. MRI slice thicknesses are generally thicker than ultrasound and are sensitive to motion. On the other hand, ultrasound is highly operator-dependant, and traditional color Doppler methods are limited to one direction. Although both methods have weaknesses, together they can provide complementary information in order to improve upon the detection and understanding of atherosclerotic plaques. Purpose: In this pilot study, we develop techniques that can combine MRI imaging with Vector Doppler imaging of the carotid artery to assess flow patterns detected by ultrasound to appearances of vessel wall and lumen on MRI. Methods: Five subjects with various types of plaques underwent both MRI and ultrasound. MRI Imaging: Using a 3.0-T scanner (Philips, Best, Netherlands), a 4element surface coil, and standardized protocol [1], 16 slices (centered at the bifurcation) of 2mm thickness were acquired with a FOV of 140 mm × 140 mm and a matrix size of 256 × 256. Four contrast weightings were used: TOF, PDW, T1W, and T2W with the latter three weightings using black-blood imaging technique. Ultrasound Imaging: A trained sonographer acquired color Doppler images at atherosclerotic plaque sites using a linear 7.5 MHz transducer (Philips, Best, Netherlands). At each site, the sonographer took two series of color Doppler images at 20° and -20°. A cross-sectional freehand sweep of the carotid was also obtained. Plaque Identification: Plaque inner and outer walls in the MRI images were outlined by a trained reviewer using in-house software (CASCADE). Vector Map Generation: Velocities and flow direction were calculated from the two color Doppler angle data for an averaged cardiac cycle (i.e., over 6 cardiac cycles, the cycles were averaged frames matched with respect to peak systole) using methods similar to previously published methods [3]. In order to represent the data, the flow direction at a particular pixel is color coded (i.e., purple is to the left, red is up, white is right, blue is down, and any other direction is a blend of the closest two colors) and overlain on the corresponding B-mode image. A second image was generated with the calculated velocities and a seven-pixel square zone of averaged directional data. The center of the zone is depicted as a box and a line from the box shows the direction of flow similar to a weathervane. Data Analysis: Using the freehand ultrasound scan as a guide, the plaques were registered between the two imaging modalities. A trained reviewer identified MRI slices with flow artifacts, which was then compared against the presence of flow reversal in the Vector Doppler images. Results: Our findings of 35 slices of matched MRI and ultrasound demonstrates a strong (i.e., a Fisher’s Exact Test P-value of 0.001) relationship between presence of flow artifact in MRI against presence of flow reversal in Ultrasound with a sensitivity and specificity of 80% 90%, respectively. Two examples are shown in Figures 1 and 2. In Figure 1, six slices of TOF and T1W show no flow artifact along the plaque. The Vector Doppler image indicated that there is no flow reversal in four different frames of the cardiac cycle (there were actually no reversals in any frame for this plaque). In Figure 2, three slices are shown for TOF, T1W, PDW, and T2W. Inside the lumen, flow artifact mimicking plaque is seen for all contrast weightings. The corresponding Vector Doppler images indicate flow reversal. Both examples demonstrate cases of association of flow artifact and flow reversal that we had expected. Conclusion: These findings suggest combining information from MRI and ultrasound can assist in MRI interpretation. Observing flow reversal in ultrasound can identify areas that may incorrectly be identified as a lesion by MRI. Ultrasound is already used for screening for plaques before acquiring MRI images, and therefore, minimal work is required to acquire two additional color Doppler readings. This additional information can be used by image reviewers to discriminate between flow artifact and actual plaque. Additionally, this can be of particular interest in monitoring plaque progression and regression in which a change in plaque morphology alters blood flow. Further studies will explore additional information made available by using these two imaging modalities for detecting and following the progression and regression of plaques as well as investigating the effects of blood flow patterns. References: 1. Yuan C, et al., NMR Biomed. 2006; 19:636654. 2. Wilhjelm JE, et al., IEEE Trans Med Imaging. 1998; 17:910-922. 3. Dunmire, B., et al., Ultrasound Med Biol. 2000; 26(8): 121335. Figure 1: Six MRI slices along a plaque are shown for both TOF (a-f) and T1W (g-l). The inner wall is outlined in red while the outer wall is in teal. A small calcium deposit is outlined in blue. The Vector Doppler calculations for a longitudinal slice of the plaque is shown as blood flow direction (m-p) and as velocity in cm/s with lines pointing in the direction of flow for a square area with a center indicated by a small box (q-t). No flow artifacts are seen in the MRI images, and no flow reversals are detected in the ultrasound images for four different frames in the cardiac cycle. Figure 2: Three MRI slices are shown for TOF (a-c), T1W (d-f), PDW (g-i), and T2W (j-l). Vector Doppler (m-p) results are shown at two points in the cardiac flow cycle. Flow artifacts (arrow) appear in all four different contrast weightings within the lumen. Flow reversal is observed in the Vector Doppler images. Table 1: Comparison of Vector Doppler Results and MRI Results MRI Results Flow Artifact No Yes Vector Doppler Flow Reversal No 20 1 Yes 5 9

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Coronary plaque morphology on multi-modality imagining and periprocedural myocardial infarction after percutaneous coronary intervention☆

Percutaneous coronary intervention (PCI) may be complicated by periprocedural myocardial infarction (PMI) as manifested by elevated cardiac biomarkers such as creatine kinase (CK)-MB or troponin T. The occurrence of PMI has been shown to be associated with worse short- and long-term clinical outcome. However, recent studies suggest that PMI defined by biomarker levels alone is a marker of ather...

متن کامل

Application of Confocal Microscopy for 3D Assessment of Carotid Plaque Structure: Implications for Carotid Blood Flow and Stroke Research.

BACKGROUND Little information is available on how forces resulting from fluid flow interact with structural stability of carotid atherosclerotic plaque and how such interactions may impact on stroke prevention; investigation of the 3D structure of plaque could help in such studies. The aim of this study was to investigate whether confocal microscopy can be used to obtain 3D visualization of the...

متن کامل

Systemic atherosclerotic plaque vulnerability in patients with Coronary Artery Disease with a single Whole Body [FDG]PET-CT scan

Objective(s): Cardiovascular disease is a leading cause of morbimortality with over half cardiovascular events occurring in the asymptomatic population by traditional risk stratification. This preliminary study aimed to evaluate systemic plaque vulnerability in patients with prior Coronary Artery Disease (CAD) with a single Whole Body [FDG] PET-CT scan in terms of plaq...

متن کامل

Multimodality MR imaging depiction of hemodynamic changes and cerebral ischemia in subarachnoid hemorrhage.

BACKGROUND AND PURPOSE Subarachnoid hemorrhage (SAH) is a common and serious neurologic emergent condition. We tested the hypothesis that multimodality MR imaging depicts changes in cerebral blood flow SAH, before any surgical or endovascular intervention, and that the frequency of these changes increases with time after ictus. METHODS We prospectively examined 37 patients with suspected SAH ...

متن کامل

The Potential of Menstrual Blood-Derived Stem Cells in Differentiation to Epidermal Lineage: A Preliminary Report

BACKGROUND Menstrual blood-derived stem cells (MenSCs) are a novel source of stem cells that can be easily isolated non-invasively from female volunteered donor without ethical consideration. These mesenchymal-like stem cells have high rate of proliferation and possess multi lineage differentiation potency. This study was undertaken to isolate the MenSCs and assess their potential in differenti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008