High-level psychophysical tuning curves: simultaneous masking by pure tones and 100-Hz-wide noise bands.
نویسندگان
چکیده
Simultaneous-masked psychophysical tuning curves were obtained from normal-hearing listeners using low-level (20-25 dB SPL) probe tones in quiet and high-level (60 dB SPL) probe tones, both in quiet and in the presence of a broad-band background noise. The background noise was introduced to eliminate combination tones or combination bands and other off-frequency listening cues that exist at high levels. Tuning curves were obtained using pure-tone maskers and 100-Hz-wide narrow-band noise maskers for probe tones at 1000 and 4000 Hz. High-level tuning curves for pure-tone maskers demonstrated large discontinuities or "notches" on the low-frequency sides of the tuning curves. Broad-band background noise eliminated those notches, indicating that the notches were due to the detection of off-frequency listening cues at combination-tone frequencies. High-level tuning curves for 100-Hz-wide narrow-band maskers also demonstrated notches on the low-frequency sides. Those notches were eliminated with broad-band background noise, which indicates that combination bands strongly influenced the shapes of high-level tuning curves obtained with narrow-band maskers. The influence of combination bands was dependent upon test frequency. At 1000 Hz, combination bands had very little influence on the shapes of high-level tuning curves. At 4000 Hz, where the masker bandwidth was substantially less than the critical bandwidth, combination bands strongly affected the low-frequency sides of the tuning curves. In 2 subjects tested at a probe frequency of 2000 Hz with 100-Hz-wide masking bands, combination bands also influenced the low-frequency sides of high-level tuning curves. The presence of combination-tone or combination-band cues essentially steepened the low-frequency slopes of tuning curves, resulting in sharper estimates of tuning. Comparisons of tuning curves obtained with pure-tone maskers and narrow-band maskers, in the same listeners, revealed that pure-tone maskers were more effective than narrow-band maskers when the masker frequencies were in the tail region of the tuning curve. The results of these experiments support the notion that tuning in the normal auditory system broadens notably with stimulus level, once off-frequency listening cues such as combination tones or combination bands are eliminated. The low-level simultaneously masked tuning curve demonstrates a sharp bandpass tuning characteristic, whereas the high-level simultaneously masked tuning curve in background noise demonstrates a broad low-pass tuning characteristic.(ABSTRACT TRUNCATED AT 400 WORDS)
منابع مشابه
High-level psychophysical tuning curves: simultaneous masking with different noise bandwidths.
Simultaneous-masked psychophysical tuning curves were measured with narrow-band noise maskers varying in bandwidth from 40 Hz to 800 Hz to determine the masker bandwidths at which combination-band detection cues no longer influence tuning-curve shapes. Tuning curves were obtained at 1000 and 4000 Hz from normal-hearing listeners using high-level (60 dB SPL) probe tones in quiet and in the prese...
متن کاملPsychophysical tuning curves measured in simultaneous and forward masking.
The level of a masker necessary to mask a probe fixed in frequency and level was determined as a function of masker frequency using a two-interval forced-choice technique. Both simultaneous- and forward- masking techniques were used. Parameters investigated include the level of the probe tone and the frequency of the probe tone. The general form of the psychophysical tuning curves obtained in t...
متن کاملAuditory masking patterns in the goldfish (Carassius auratus): psychophysical tuning curves.
The masking effects of tones on the detection auditory signals were studied in goldfish using the psychophysical tuning-curve paradigm. For signals below 350 Hz, masking is an inverse function of the frequency separation between masker and signal; a finding consistent with previous masking studies on fishes, birds and mammals. For signals above 350 Hz, masking peaks occur both in the 350 Hz reg...
متن کاملIpsilateral masking between acoustic and electric stimulations.
Residual acoustic hearing can be preserved in the same ear following cochlear implantation with minimally traumatic surgical techniques and short-electrode arrays. The combined electric-acoustic stimulation significantly improves cochlear implant performance, particularly speech recognition in noise. The present study measures simultaneous masking by electric pulses on acoustic pure tones, or v...
متن کاملAn analysis of psychophysical tuning curves in normal and pathological ears.
Simultaneous psychophysical tuning curves were obtained from normal-hearing and hearing-impaired listeners, using probe tones that were either at similar sound pressure levels or at similar sensation levels for the two types of listeners. Tuning curves from the hearing-impaired listeners were flat, erratic, broad, and/or inverted, depending upon the frequency region of the probe tone and the fr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of speech and hearing research
دوره 34 2 شماره
صفحات -
تاریخ انتشار 1991