Indirect Complexometric Determination of Mercury Using Potassium Iodide as Selective Masking Agent
نویسنده
چکیده
This paper describes a indirect complexometric method for the determination of mercury in the presence of co-ions, based on the selective masking ability of potassium iodide. To the mixture of mercury (II) and other metal ion solution, EDTA solution was added in excess of the metal ions present. The pH of the solution was adjusted to 5.0-6.0 using solid hexamine (10 ± 2 g) and surplus EDTA was titrated with zinc sulfate solution using xylenol orange indicator. An excess of solid potassium iodide was then added to decompose the Hg-EDTA complex and the released EDTA was titrated with standard zinc sulfate solution. Accurate results were obtained for 4.5-80 mg (2.24 ×10−5 M 3.99 ×10−4 M) of mercury with relative errors ≤ 0.4 %, standard deviations ≤ 0.07 mg. Sn(IV) and Au(III) interferes but can be masked using sodium fluoride. The method can be applied in the analysis of mercury in its alloys and complexes.
منابع مشابه
Selective masking and demasking for the stepwise complexometric determination of aluminium, lead and zinc from the same solution
BACKGROUND A complexometric method based on selective masking and de-masking has been developed for the rapid determination of aluminium, lead and zinc from the same solution in glass and glass frit samples. The determination is carried out using potassium cyanide to mask zinc, and excess disodium salt of EDTA to mask lead and aluminium. The excess EDTA was titrated with standard Mn(II)SO(4 )so...
متن کاملImproved Extraction-Separation of Lanthanum/ Europium Ions by Bis(2-ethylhexyl)phosphoric Acid Using 12-Crown-4 as an Ion Selective Masking Agent
The extraction-separation of lanthanum and europium ions with bis(2-ethylhexyl) phosphoric acid (DEHPA) in cyclohexane was improved by adding 12-crown-4 (12C4) to the aqueous phase as a masking agent. In the presence of this crown ether the extraction curve of lanthanum ions versus pH shifts to the higher pH region, while the curve is not influenced for the europium ions. Consequently the s...
متن کاملChemically modified carbon paste electrode for iodide determination on the basis of cetyltrimethylammonium iodide ion-pair.
A new carbon paste electrode (CPE) for the determination of iodide ion based on a cetyltrimethylammonium iodide (CTMAI) ion pair as an electroactive material is described. The electrode shows a linear response for iodide ion over the concentration range of 4 x 10(-5) M to 1 x 10(-1) M with a lower detection limit of 4 x 10(-5) M at 25 degrees C. The electrode has a Nemstian slope of -55.0 +/- 0...
متن کاملMasking Agents Evaluation for Lead Determination by Flow Injection-Hydride Generation-Atomic Fluorescence Spectrometry Technique: Effect of KI, L-Cysteine, and 1,10-Phenanthroline
Hydride generation (HG) of lead technique presents interferences from foreign ions of complex matrix samples. In order to minimize these interferences, the effect of masking agents such as KI, L-cysteine, and 1,10-phenanthroline was studied in the absence and in the presence of selected interfering species (As, Cr, Cu, and Fe). Different modes of addition of masking agents were accomplished, th...
متن کاملApplication of Differential Kinetic Method Using ANN with a New Synthetic Reagent for Simultaneous Spectrophotometric Determination of Mercury and Palladium
A new selective reagent was used for simultaneous determination of mercury and palladium in real samples with their different kinetic spectrophotometric properties. The method is based on the difference in the rate of the oxidation reaction of the recently synthesized reagent, nitro benzoyl diphenylmethylen phosphorane (N-BDMP), with Hg2+ and Pd2+. The kinetic profiles were monitored and record...
متن کامل