Straight SU-8 pins

نویسندگان

  • R Safavieh
  • M Pla Roca
  • M A Qasaimeh
  • M Mirzaei
چکیده

SU-8 can be patterned with high resolution, is flexible and tough. These characteristics qualify SU-8 as a material for making spotting pins for printing DNA and protein microarrays, and it can potentially replace the commonly used silicon and steel pins that are expensive, brittle in the case of silicon and can damage the substrate during the printing process. SU-8, however, accumulates large internal stress during fabrication and, as a consequence, thin and long SU-8 structures bend and coil up, which precludes using it for long, freestanding structures such as pins. Here we introduce (i) a novel fabrication process that allows the making of 30 mm long, straight spotting pins that feature (ii) a new design and surface chemistry treatments for better capillary flow control and more homogeneous spotting. A key innovation for the fabrication is a post-processing annealing step with slow temperature ramping and mechanical clamping between two identical substrates to minimize stress buildup and render it symmetric, respectively, which together yield a straight SU-8 structure. SU-8 pins fabricated using this process are compliant and resilient and can buckle without damage during printing. The pins comprise a novel flow stop valve for accurate metering of fluids, and their surface was chemically patterned to render the outside of the pin hydrophobic while the inside of the slit is hydrophilic, and the slit thus spontaneously fills when dipped into a solution while preventing droplet attachment on the outside. A single SU-8 pin was used to print 1392 protein spots in one run. SU-8 pins are inexpensive, straightforward to fabricate, robust and may be used as disposable pins for microarray fabrication. These pins serve as an illustration of the potential application of ultralow stress SU-8 for making freestanding microfabricated polymer microstructures. S Online supplementary data available from stacks.iop.org/JMM/20/055001/mmedia

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the accuracy of linear and angular measurements on panoramic radiographs taken at different positions

PURPOSE This study assessed the accuracy of linear and angular measurements on panoramic radiographs taken at different positions in vitro. MATERIALS AND METHODS Two acrylic models were fabricated from a cast with normal occlusion. Straight and 75° mesially and lingually angulated pins were placed, and standardized panoramic radiographs were taken at standard position, at an 8° downward tilt ...

متن کامل

Thermal Performance of an Elliptical Pin Fin Heat Sink

Christopher L. Chapman, and Seri Lee Aavid Engineering, Inc. Laconia, New Hampshire 03247 Bill L. Schmidt Silicon Graphics Computer Systems Mountainview, California 94039 Comparative thermal tests have been carried out using aluminum heat sinks made with extruded fin, cross-cut rectangular pins, and elliptical shaped pins in low air flow environments. The elliptical pin heat sink was designed t...

متن کامل

On the Memorability of System-generated PINs: Can Chunking Help?

To ensure that users do not choose weak personal identification numbers (PINs), many banks give out system-generated PINs, using computers to generate random PINs. 4-digit is the most commonly used PIN length, but 6-digit system-generated PINs are also becoming popular. The increased security we get from using system-generated PINs, however, comes at the cost of memorability. And while banks ar...

متن کامل

Effect of the number of pins and inter-pin distance on somatosensory evoked magnetic fields following mechanical tactile stimulation

Magnetoencephalography (MEG) recordings were collected to investigate the effect of the number of mechanical pins and inter-pin distance on somatosensory evoked magnetic fields (SEFs) following mechanical stimulation (MS). We used a 306-ch whole-head MEG system. SEFs were elicited through tactile stimuli with 1-, 2-, 3-, 4- and 8-pins using healthy participants. Tactile stimuli were applied to ...

متن کامل

Rehabilitation of long-span Kennedy class IV partially edentulous patient with a custom attachment-retained prosthesis

The rehabilitation of a patient in the Kennedy class IV situation demands biomechanical balance and aesthetic improvement. The long-span condition complicates the problem because of the unavailability of sufficient number of abutments to support the prosthesis. Conventional removable prosthesis and fixed partial denture are not advised for the same reason. This report describes a novel techniqu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010