OBJECTIVE To test the efficiency of the direct duplex scanning parameters in the diagnosis of renal artery stenosis (RAS), and verify whether or not the cut-off points recommended by medical literature are the most appropriate means to distinguish lesion severity. METHODS Prospective study, including 62 patients with RAS, submitted to a duplex ultrasound scan and selective arteriography. The peak systolic velocity (PSV) and the renal-aortic ratio (RAR) were measured. Statistical analysis included the ROC (receiver operating characteristic curve), unpaired students t-test, sensitivity, specificity, positive and negative predictive values and accuracy. RESULTS The arteriography revealed RAS 0-59% in 31 arteries (24%); RAS 60-99% in 91 arteries (72%) and 5 occlusions (4%). ROC analysis demonstrated that the lesion detection efficiency of PSV and RAR were similar with areas below the curves of 0.96 and 0.95, respectively. Considering the cut-off points recommended by medical literature, PSV of 180 cm/sec presented a sensitivity of 100% and specificity of 81%, while the RAR of 3.5 presented a sensitivity of only 79%, with a specificity of 93%. These parameters were analyzed in conjunction (direct criteria) revealing a sensitivity of 79% and specificity of 97%. The optimized cut-off points were: PSV of 189 cm/sec and RAR of 2.6, demonstrating sensitivity and specificity rates of 100%, 87%, 96% and 87% respectively. CONCLUSION The individual use of optimized peak systolic velocity (PSV) was the most efficient parameter in the detection and grading of RAS.
منابع مشابه
گزارش یک مورد آنژیوپلاستی و Stent گذاری موفق در درمان تنگی
Introduction: Renal transplantation has established itself as the treatment of choice for the majority of patients with End stage renal failure(ESRF). Arterial stenosis is the most common vascular complication after kidney transplantation, occurring in approximately 4%-25% of transplant recipients. Case Report: The patient is a 68 year old man with ESRF due to Poly cystic kidney disease(PCK...
متن کاملMITRAL STENOSIS COMPLICATED BY RENAL ARTERY EMBOLISM
Six patients with mitral stenosis complicated by renal artery embolism studied prospectively are presented. In five patients there was unilateral and in one patient bilateral renal artery involvement. The diagnosis was confirmed by intravenous pyelography, retrograde pyelography, renal angiography, renal scan or a combination of these. All had atrial fibrillation, proteinuria and elevated ...
متن کاملRenal artery stenosis: evaluation with colour duplex ultrasonography.
BACKGROUND Detection of renal artery stenoses (RAS) by means of duplex Doppler ultrasound with direct scanning of the main renal arteries is subject to numerous limitations. Using semiquantitative analysis of the Doppler curve, which can be recorded from intrarenal arteries, it is possible to detect RAS unaffected by the problems of direct Doppler scanning of the renal arteries. METHODS Both ...
متن کاملبررسی میزان شیوع تنگی شریان کلیه به دنبال آنژیوگرافی عروق کرونر و عوامل مرتبط با آن در بیماران مبتلا به فشارخون کاندید آنژیوگرافی عروق کرونر در بیمارستان افشار یزد
Introduction: Renal artery stenosis is the most prevalent disease of renal artery and has an important role in making hypertension and renal atrophy. Since in previous researches, despite high frequency of risk of cardiovascular disease in Iran, there did not exist any general research investigating risk factors of coronary artery disease and incidence of contemporary renal artery stenisis, ...
متن کاملRole of duplex scanning for the detection of atherosclerotic renal artery disease.
To assess the accuracy of renal artery duplex scanning for the purpose of diagnosing atherosclerotic renal artery stenosis, we compared the findings of renal arteriograms to the results of duplex scanning in 41 patients. Using an increase of renal artery peak systolic flow velocity of greater than 180 cm/sec, duplex scanning was able to discriminate normal from diseased renal arteries with a se...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Arquivos brasileiros de cardiologia
دوره 87 3 شماره
صفحات -
تاریخ انتشار 2006