ARTEMIS observations of lunar pickup ions: Mass constraints on ion species

نویسندگان

  • X.-Z. Zhou
  • V. Angelopoulos
  • A. R. Poppe
  • J. S. Halekas
چکیده

[1] Observations of heavy ions of lunar origin give important information regarding lunar exospheric processes, especially with respect to exospheric particle abundance and composition. Electrostatic analyzers without a time-of-flight section provide highly sensitive, absolute density detection but without mass discrimination. Here we place constraints on lunar ion species through inference of the average ion mass using such instruments. The technique is based on the plasma quasi-neutrality requirement, an independent electron density measurement, and the fact that electrostatic analyzers underestimate the ion density by the square root of the ion mass. Applied to a case of such observations by ARTEMIS in the terrestrial lobe reported by Poppe et al. (2012), our technique suggests an average mass of 28 amu for lunar pickup ions. This result, consistent with the lower limit of 24 amu derived in the Poppe et al. model, suggests that the observed ions were most likely Al+ and Si+. The technique is also refined and applied to a more complicated event with a series of heavy ion surges in the plasma sheet, to show the spatial and/or temporal dependence of the observed lunar ion species. The technique is particularly timely given the planned conjunctions and coordinated lunar studies by NASA’s Acceleration, Reconnection, Turbulence and Electrodynamics of the Moon’s Interaction with the Sun (ARTEMIS) and Lunar Atmosphere and Dust Environment Explorer missions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Model-based constraints on the lunar exosphere derived from ARTEMIS pickup ion observations in the terrestrial magnetotail

[1] We use Acceleration, Reconnection, Turbulence and Electrodynamics of the Moon’s Interaction with the Sun (ARTEMIS) measurements of lunar exospheric pickup ions in the terrestrial magnetotail lobes combined with a particle-tracing model to constrain the source species and distributions of the lunar neutral exosphere. These pickup ions, generated by photoionization of neutral species while th...

متن کامل

Lunar pickup ions observed by ARTEMIS: Spatial and temporal distribution and constraints on species and source locations

[1] ARTEMIS observes pickup ions around the Moon, at distances of up to 20,000 km from the surface. The observed ions form a plume with a narrow spatial and angular extent, generally seen in a single energy/angle bin of the ESA instrument. Though ARTEMIS has no mass resolution capability, we can utilize the analytically describable characteristics of pickup ion trajectories to constrain the pos...

متن کامل

Using ARTEMIS pickup ion observations to place constraints on the lunar atmosphere

[1] We present a method for deriving constraints on the structure and composition of the lunar atmosphere by using pickup ion measurements from ARTEMIS, mapping observed fluxes from the spacecraft location to derive production rates at the source region, and fitting to a parameterized neutral atmosphere model. We apply this technique to ~12min of high-resolution burst data collected by ARTEMIS ...

متن کامل

ARTEMIS observations of lunar dayside plasma in the terrestrial magnetotail lobe

[1] We report observations by the dual-probe Acceleration, Reconnection, Turbulence and Electrodynamics of the Moon’s Interaction with the Sun (ARTEMIS) mission of Moon-related electron and ion signatures obtained above the dayside lunar surface in the terrestrial magnetotail lobes. While the Moon is often thought of as a passive absorber, recent observations from Kaguya, Chandrayaan, Chang’E, ...

متن کامل

The Lunar Atmosphere and Its Study by Lro

Current Understanding: The atmosphere of the Moon is extremely tenuous, with a total mass of only ~10 kg (i.e., at STP it would fit inside a large building) [1]. Since it is so thin, the lunar atmosphere is difficult to detect, and has only been partially sampled in situ on the nightside by Apollo pressure gauges & mass spectrometers (these were swamped by contamination on the dayside) [2]. Lik...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013