Can blood pressure be measured during exercise with an automated sphygmomanometer based on an oscillometric method?

نویسندگان

  • Tomoyuki Shinohara
  • Naoko Tsuchida
  • Kanako Seki
  • Tomohiro Otani
  • Tatsuya Yamane
  • Yamato Ishihara
  • Chinatsu Usuda
چکیده

[Purpose] This study investigated the reliability of an automated sphygmomanometer based on an oscillometric method, when used during exercise. [Subjects and Methods] Ten healthy subjects were included. Blood pressure (BP) was measured with an automated sphygmomanometer based on a cuff-oscillometric method. The experiment consisted of five tests: sitting posture at rest, walking with swinging the upper limbs, walking without swinging the upper limbs, walking on a treadmill, and riding a bicycle ergometer. Right and left brachial artery BP was measured twice at the same times. If the difference in systolic BP on bilateral testing was less than 15 mmHg, it was judged to be accurate, and accurate measurement rates were calculated. [Results] BP could not be measured in most limbs on walking with swinging the upper limbs, walking without swinging the upper limbs, or walking on a treadmill. The accurate measurement rates in bilateral limbs were 95.0% in sitting posture at rest, 0.0% on walking with swinging upper limbs, 5.0% on walking without swinging upper limbs, 15.0% on walking on a treadmill, and 65.0% on riding a bicycle ergometer. [Conclusion] An automated sphygmomanometer based on an oscillometric method was useful for BP measurement only at rest.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Various Blood Pressure Measurement Techniques with Standard Office Based Blood Pressure Mesurement

Introduction: In order to control Hypertension, it is necessary to understand the methods of blood pressure measurement. Recent guidelines emphasize on employing appropriate blood pressure measurement techniques and white coat hypertension. Definition and methods of blood pressure measurement have changed in the American guideline based on SPRINT trial (Systolic Blood Pressure Intervention Tria...

متن کامل

Similarity between blood pressure values assessed by auscultatory method with mercury sphygmomanometer and automated oscillometric digital device.

INTRODUCTION One of the biggest challenges in the management of hypertension is adequate blood pressure (BP) control. To achieve this goal, home blood pressure measurement (HBPM) with automated devices has been encouraged. However, part of the medical community still disputes its validity, believing that HBPM may lead to incorrect readings. OBJECTIVE To evaluate the correspondence between the...

متن کامل

Automated sphygmomanometers should not replace manual ones, based on current evidence.

To the Editor: Myers et al.1 in their article “Comparison Between an Automated and Manual Sphygmomanometer in a Population Survey” compared blood pressures (BPs) measured with a standard mercury sphygmomanometer and an oscillometric sphygmomanometer and concluded that “conventional manual BP readings taken using mercury sphygmomanometry can be replaced by (readings taken using) a validated, aut...

متن کامل

Arterial stiffness as underlying mechanism of disagreement between an oscillometric blood pressure monitor and a sphygmomanometer.

Oscillometric blood pressure devices tend to overestimate systolic blood pressure and underestimate diastolic blood pressure compared with sphygmomanometers. Recent studies indicate that discrepancies in performance between these devices may differ between healthy and diabetic subjects. Arterial stiffness in diabetics could be the underlying factor explaining these differences. We studied diffe...

متن کامل

Improving the Design of Blood Pressure and Blood Saturation Monitors

A blood pressure monitor or sphygmomanometer can be either manual or automatic, employing respectively either the auscultatory method or the oscillometric method. The manual version of the sphygmomanometer involves an inflatable cuff with a stethoscope adopted to detect the sounds generated by the arterial walls to measure blood pressure in an artery. An automatic sphygmomanometer can be effect...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 29  شماره 

صفحات  -

تاریخ انتشار 2017