Estimation for error sources for optical head tracking in cranial radiation therapy

نویسندگان

  • Philipp Grüning
  • Patrick Stüber
  • Lars Richter
  • Oliver Blanck
  • Ralf Bruder
  • Achim Schweikard
چکیده

There is a growing demand for high-accuracy and frameless solutions for cranial radiation therapy. Among different approaches for intra-fractional head tracking using X-Ray or MV imaging or Cone Beam CT, optical head tracking in particular promises high spatial and temporal resolution with a minimum of system latency and no additional dose exposition. It may therefore be ideal for motion-compensated or high-accuracy cranial radiation therapy. Nevertheless, up to now optical systems lack accuracy and are therefore only found in prototypes or test setups. Using a consumer-grade optical rangefinder, we have built a test setup to systematically quantify critical error sources for tracking systems based on triangulation. Subsequently, we present and discuss potential solutions to minimize the error.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Approach to Improve Accuracy of Optical Tracking Systems in Cranial Radiation Therapy

This work presents a new method for the accurate estimation of soft tissue thickness based on near infrared (NIR) laser measurements. By using this estimation, our goal is to develop an improved non-invasive marker-less optical tracking system for cranial radiation therapy. Results are presented for three subjects and reveal an RMS error of less than 0.34 mm.

متن کامل

Calculation of gel dose after external radiation therapy using optical CT

In this study, the MAGIC- f polymer gel was used to determine the absorbed dose by external radiation therapy. The MAGIC- f gel was made under normal pressure and temperature conditions and irradiated with a Siemens 6MV linear accelerator at 10 × 10 cm2 and at a depth of 10 cm. While simulating the head of the accelerator unit by the Monte Carlo method with BEAMnrc code, the percentage depth do...

متن کامل

Estimation of radiation dose to the lens of eyes of patients undergoing cranial computed tomography in a teaching Hospital in Osun state, Nigeria

Background: One of the means of assessing dose to patients from Computed tomography (CT) procedure is through the determination of the skin entrance dose (ESD) with the appreciation of the concern that ocular exposure effects from CT scan includes possible induction of cancer and cataract. Due to the relatively more recent introduction of CT scans, little work has been done in this area in the ...

متن کامل

Utilization of Electronic Portal Imaging Device (EPID) For Setup Verification and Determination of Setup Margin in Head and Neck Radiation Therapy

Introduction: Radiation therapy involves a multistep procedure; therefore, the error in patient set up is an inherent part of the treatment. Main purpose of this study was to determine the clinical target volume (CTV) to planning target volume (PTV) in head and neck cancer patients. Material and Methods: A total of 15 patients who had daily p...

متن کامل

A study on the accuracy of motion tracking of thoracic tumors at radiotherapy with external surrogates

Introduction: In radiotherapy with external surrogates, exact information of tumor position is one of the key factors that improves treatment delivery. Many dynamic tumors in thorax region of patient move mainly due to respiration and are known as intra-fractional motion error that must be compensated, as well. One of clinical strategy is using Stereotactic Body Radiation Thera...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012