Total cost of high volume multi-detector CT data management

نویسندگان

  • D. R. Voellmy
  • O. Handgrätinger
  • Simon Wildermuth
  • B. Fröhlich
  • Borut Marincek
چکیده

The number of CT images increased significantly when 16-row multi-detector CT scanners (MDCT) were introduced. The purpose of this study is to quantify the total data management cost of MDCTand to identify cost drivers. An activity-based costing (ABC) method was used to analyze cost drivers in MDCT data management. Changing from 4-row to 16-row CT, mean image count per exam was increased from 699 to 1465 images per exam, reaching up to 18,000 images per exam. Cost analysis was implemented in four steps: (1) identify activities; (2) assign direct costs to activities; (3) define bases for indirect costs; (4) assign indirect cost to the activities. Four major activities were identified in MDCT data management: PACS check-in, data handling during digital reporting, storage, and hospital-wide digital image distribution. Total direct and indirect costs were $49 per mean exam. With $15.27 per exam, storage turned out to be the main cost driver. Therefore, two scenarios for selective storage are discussed. When 50% of the images are deleted before long-term storage, savings of $7.63 per exam are achieved, while additional labor cost for data selection is only $4.55 per exam. When 80% of the images are deleted in a labor-intensive process, savings of $9.11 per examwill result. Awhat-if-analysis shows that long-term storage ofMDCT data is cost-effective below a storage cost of $8.40 per exam. Given the actual total cost of ownership (TCO) of $53 per GB, high performance storage is not cost-effective for long-term storage of high volume MDCT data. If the storage price decay of annually 45% continues, the break-even cost of $8.40 per examwill be reached in the next 1– 2 years. In themeantime, only the most relevant parts ofMDCTexams should be kept, or low cost mass storage media should be used to optimize the cost–value relation.D 2004 CARS and Elsevier B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

4D Cardiac Reconstruction Using High Resolution CT Images

Recent developments on the 320 multi-detector CT technologies have made the volumetric acquisition of 4D high resolution cardiac images in a single heart beat possible. In this paper, we present a framework that uses these data to reconstruct the 4D motion of the endocardial surface of the left ventricle (LV) for a full cardiac cycle. This reconstruction framework captures the motion of the ful...

متن کامل

Design of High-Efficiency and Low-Cost Six-Phase Permanent Magnet Synchronous Generator for Direct-Drive Small-Scale Wind Power Application

Permanent magnet synchronous generators (PMSG) have a huge potential for direct-drive wind power applications. Therefore, optimal design of these generators is necessary to maximize their efficiency and to reduce their manufacturing cost and total volume. In this paper, an optimal design of a six-phase 3.5 KW direct-drive PMSG to generate electricity for domestic needs is performed. The aim of ...

متن کامل

A Multi Objective Optimization Approach for Resources Procurement of Bank

Calculating total cast of bank resources procurement methods which include current -free loan deposit, saving interest-free loan deposit, regular and net short-term investment deposit, long-term investment deposit and surety bond cash deposit and presenting their optimal integration require precise scientific studies. Hence, this study is an attempt to know which methods are the best optimal in...

متن کامل

Estimation of the cost function of a two-echelon inventory system with lost sales using regression

Multi-echelon inventory systems are one of the most important and attractive areas in modelling supply chain management so that several researches and studies have been done about. In this paper, the total cost function of a two-echelon inventory system with central warehouse and many identical retailers controlled by continuous review inventory policy is estimated. We have assumed the demand i...

متن کامل

Three-dimensional imaging of thoracic diseases with multi-detector row CT.

The benefits of multi-detector row CT (MDCT) relative to single-detector row helical CT are considerable. Multi-detector row CT allows shorter acquisition times, greater coverage, and superior image resolution. These factors substantially increase the diagnostic accuracy of the examination. Three-dimensional (3D) volume data from MDCT provides various unique applications on thoracic diseases. T...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004