STAN S21 fetal heart monitor for fetal surveillance during labor: an observational study in 637 patients.
نویسندگان
چکیده
OBJECTIVE To assess the value of the STAN fetal heart monitor for intrapartum fetal monitoring using cardiotocography (CTG) and fetal electrocardiography (ECG). DESIGN Prospective observational study. MATERIAL AND METHODS Between August 2000 and November 2002, 637 high-risk labors were monitored using a STAN S21 fetal heart monitor, providing CTG plus automatic ST analysis of the fetal ECG. Guidelines with recommendations about when to intervene were available. During the study period labor-ward personnel were systematically instructed about the (patho)-physiology of asphyxia and CTG and ST changes during labor. RESULTS Four hundred and forty-nine recordings were available for analysis of outcome in relation to ST changes. In 61 cases, ST changes requiring intervention occurred > 10 min before birth. In 35 (57%) of these cases, umbilical artery blood pH at delivery was < 7.15. Eighteen (4.0%) neonates were born with metabolic acidosis (umbilical artery pH < 7.05 and extracellular base deficit > 12 mmol/l). Significant ST changes (18-31 min before birth) were present in all five cases with pH < 7.00 and in six of the 13 cases with pH of 7.00-7.04 (false-negative rate 1.6%). Neonatal follow-up showed no adverse outcome. One hundred and ninety-two fetal blood samples (121 in the first stage and 71 in the second stage of labor) were taken from 142 women. Fetal scalp blood pH was < 7.15 in ten samples, 7.15-7.19 in 11 samples, 7.20-7.24 in 30 samples and > or =7.25 in 141 samples. ST changes occurred in eight (80%), six (55%), nine (30%) and 15 (11%) of these cases, respectively. In 188 (29.5%) women, outcome could not be analyzed in relation to ST changes because of inadequate recording (time between end of recording and delivery > 20 min or poor signal quality) or the absence of umbilical cord gases. In this group, four (2.1%) neonates with metabolic acidosis were born. In three of these cases the fetal ECG signal was of was poor quality and in one case the recording had ended 60 min before birth. CONCLUSION ST changes were present in all five cases with severe metabolic acidosis (umbilical artery pH < 7.00). ST changes occurred in 46% of cases with mild metabolic acidosis. CTG plus ST analysis was more specific in detecting fetal acidemia than CTG alone.
منابع مشابه
Fetal electrocardiotocography in labor and neonatal outcome: an observational study in 1889 patients in the French center of Edouard Herriot, Lyon.
BACKGROUND The STAN methodology has been shown to reduce both operative delivery for fetal distress and the cord artery metabolic acidosis rate. OBJECTIVE The objective of this study was to monitor delivery modes and perinatal outcomes following the introduction of the STAN methodology and the evolution of its use at our institution. METHODS Two periods were characterized: June 2000-June 20...
متن کاملReview of the first 1502 cases of ECG-ST waveform analysis during labour in a teaching hospital.
OBJECTIVE To assess the impact of introduction of the STAN monitoring system. STUDY DESIGN Prospective observational study. SETTING Tertiary referral labour ward, St George's Hospital, London. POPULATION High-risk term pregnancies. METHODS We report all consecutive cases of intrapartum monitoring using the STAN S 21 fetal heart monitor. Cases with adverse neonatal outcome were evaluated...
متن کاملSTAN in clinical practice--the outcome of 2 years of regular use in the city of Gothenburg.
OBJECTIVE The purpose of this study was to monitor the introduction of the STAN-methodology (Noventa Medical, Moelndal, Sweden). STUDY DESIGN This was a prospective observational study covering the total population of deliveries at term during 2 years. Four thousand eight hundred and thirty out of 14,687 term pregnancies were monitored using the STAN S 21 fetal heart monitor and the associate...
متن کاملارتباط احساس کاهش حرکت جنین توسط مادر حامله ترم با میزان عوارض جنین در طی زایمان
Introduction: The maternal perception of fetal movements at term has been used as an evaluative test of fetal wellbeing since the last 30 years, but there are different reports about its value. The aim of this study was evaluation of decreased fetal movement and relation to situation of fetus in uterus. It is significant that we understand the relationship between decreased fetal movement and i...
متن کاملEffectiveness of pulse oximetry versus fetal electrocardiography for the intrapartum evaluation of nonreassuring fetal heart rate.
OBJECTIVES To compare the effectiveness of pulse oximetry and fetal electrocardiography in the management of labor with nonreassuring fetal heart rate (NRFHR). STUDY DESIGN This randomized experimental study consisted of two arms. In group 1 we used pulse oximetry and in group 2 we used STAN® technology. The participants in each group were 90 pregnant women with a full-term singleton fetus in...