Scan Mode Performance of Dual Energy X-ray Absorptiometry Bone Densitometer
نویسندگان
چکیده
Objective: A commercially available dual energy X-ray absorptiometry scanner normally provides more than 1 scan mode. The differences between scan modes affect scan time, received radiation dose, and quality of the scan image. A phantom study was performed to evaluate the performance of different scan modes for anteriorposterior spine scan. Patients and Methods: To measure the entrance skin exposure, an ionization chamber was placed on the scanning table in the central region. For a QDR Delphi dual energy X-ray absorptiometry scanner, 4 scan modes were available for spine study. Results: The fastest scan mode, turbo mode, was found to produce underestimated results for total area of the vertebrae (~1%), bone mineral content (~7%), and bone mineral density (~6%). In contrast, the slowest scan mode, high definition mode, was found to produce overestimated bone mineral content (~3%) and bone mineral density (~2%). The results from the default fast array scan mode and the remaining array scan mode were found to be accurate and no significant difference was found between them. Conclusion: Since the fast array scan mode required 50% less scan time and the measured entrance skin dose was also approximately 50% less than the array scan mode, the fast array mode is considered to be the choice for routine clinical spine studies. The turbo scan mode should only be used as an aid in positioning the patient prior to performing a scan.
منابع مشابه
Comparison of Bone Mineral Density Measured by Dual X-ray, Axial Dual-energy Photon X-ray Absorptiometry and Laser Absorptiometry of Calcaneus
The objective of this study was to validate the use of bone mineral measurements of the calcaneus bone by dual X-ray and laser (DXL) in a cross-sectional study carried out in an osteoporosis clinic. Measurements of bone mineral density (BMD) at proximal femur and spine were obtained by dual-energy photon X-ray absorptiometry (DEXA). Osteoporosis was defined by a DEXA T-score <-2.5 at the femora...
متن کاملDual-energy X-ray absorptiometry diagnostic discordance between Z-scores and T-scores in a young Iranian population
Background: Dual-energy X-ray Absorptiometry (DXA) is considered the gold standard for non-invasive measurement of bone mass. T-scores and Z-scores are used to present the results of bone mass. The present study was designed to evaluate the discordance between T-scores and Z-scores calculated at a same level and its relation with age, gender and body mass index (BMI) in a representative sampl...
متن کاملComparison of Singh index accuracy and dual energy X-ray absorptiometry bone mineral density measurement for evaluating osteoporosis
Background: The Singh index is an inexpensive simple method to evaluate bone density, commonly used to assess osteoporosis is based on the radiological appearance of the trabecular bone structure of the proximal femur on a plain antero-posterior (AP) radiograph. The purpose of this study was to compare between Singh index and bone mineral density measurement using dual energy X-ray abs...
متن کاملScreening for vertebral fracture with dual x-ray absorptiometry.
Vertebral fractures are highly prevalent in the elderly population, and epidemiologic studies have found that these fractures are associated with an increased risk of future spine or hip fractures independent of bone mineral density. Only 20%-30% of vertebral fractures are recognized clinically; the rest are discovered incidentally on lateral spine radiographs. Lateral spine x-rays have not bee...
متن کاملDetermination of the Precision of Dual Energy X-ray Absorptiometry (dexa) When Applied at the Knee
Introduction: Dual energy x-ray absorptiometry (DEXA) is one of the most widely used methods measuring periprosthetic bone mineral density (BMD). Several reports have presented the precision of DEXA when used at the hip, whereas similar reports on factors influencing the precision at the knee are sparse. There are two noticeable aspects when measuring BMD at the knee. First, no software specifi...