Sources and effects of electrode impedance during deep brain stimulation.

نویسندگان

  • Christopher R Butson
  • Christopher B Maks
  • Cameron C McIntyre
چکیده

OBJECTIVE Clinical impedance measurements for deep brain stimulation (DBS) electrodes in human patients are normally in the range 500-1500 Omega. DBS devices utilize voltage-controlled stimulation; therefore, the current delivered to the tissue is inversely proportional to the impedance. The goals of this study were to evaluate the effects of various electrical properties of the tissue medium and electrode-tissue interface on the impedance and to determine the impact of clinically relevant impedance variability on the volume of tissue activated (VTA) during DBS. METHODS Axisymmetric finite-element models (FEM) of the DBS system were constructed with explicit representation of encapsulation layers around the electrode and implanted pulse generator. Impedance was calculated by dividing the stimulation voltage by the integrated current density along the active electrode contact. The models utilized a Fourier FEM solver that accounted for the capacitive components of the electrode-tissue interface during voltage-controlled stimulation. The resulting time- and space-dependent voltage waveforms generated in the tissue medium were superimposed onto cable model axons to calculate the VTA. RESULTS The primary determinants of electrode impedance were the thickness and conductivity of the encapsulation layer around the electrode contact and the conductivity of the bulk tissue medium. The difference in the VTA between our low (790 Omega) and high (1244 Omega) impedance models with typical DBS settings (-3 V, 90 mus, 130 Hz pulse train) was 121 mm3, representing a 52% volume reduction. CONCLUSIONS Electrode impedance has a substantial effect on the VTA and accurate representation of electrode impedance should be an explicit component of computational models of voltage-controlled DBS. SIGNIFICANCE Impedance is often used to identify broken leads (for values > 2000 Omega) or short circuits in the hardware (for values < 50 Omega); however, clinical impedance values also represent an important parameter in defining the spread of stimulation during DBS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relationship of the P Angle with Stereotactic Arc in Intraoperative Outcome of Patients with Parkinson’s Disease Undergoing Deep Brain Stimulation

Background & Aim: DBS (deep brain stimulation) is a new and successful technique in treatment of symptoms of&nbsp;Parkinsonism especially after drug resistance. Research in this field is mostly designed for evolution of this technique.&nbsp;The present study aimed at evaluating the relationship between the angle formed in midsagittal and STN (sub-thalamic&nbsp;nucleus) axis line and recording l...

متن کامل

Variation in deep brain stimulation electrode impedance over years following electrode implantation.

BACKGROUND Deep brain stimulation (DBS) electrode impedance is a major determinant of current delivery to target tissues, but long-term variation in impedance has received little attention. OBJECTIVES To assess the relationship between electrode impedance and time in a large DBS patient population and characterize the relationship between contact activity and impedance. METHODS We collected...

متن کامل

O10: Deep Brain Stimulation and Psychiatry

The use of deep brain stimulation in psychiatric disorders has received great interest owing to the small risk of the operation, the reversible nature of the technique, and the possibility of optimizing treatment postoperatively. Currently deep brain stimulation in psychiatry is investigated for obsessive-compulsive disorder, Gilles de la Tourette’s syndrome and major depression. This presentat...

متن کامل

Principles of Within Electrode Current Steering (WECS)

Transcranial Direct Current Stimulation (tDCS) is a neuromodulation technique that involves non-invasive delivery of weak direct current (1-2 mA) to the brain. Conventionally, tDCS employs rectangular saline-soaked sponge pads (25-35 cm) placed on the scalp, with an internal electrode connected to the current source. Impedance measurement across the current source output may fail to recognize n...

متن کامل

Control of epileptic seizures by electrical low frequency deep brain stimulation: A review of probable mechanisms

Epilepsy is the most common neurological disease with no definitive method in treatment. Notably, the main way to treat and control epileptic seizures is drug therapy. However, about 20-30% of patients with epilepsy are drug resistant and require other therapeutic manners. Deep brain stimulation is a new therapeutic strategy for these patients. Conspicuously, there are no clear answers for basi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology

دوره 117 2  شماره 

صفحات  -

تاریخ انتشار 2006