Influence of Bioaerosol Source Location and Ceiling Fan Direction on Eggcrate Upper-room Ultraviolet Germicidal Irradiation
نویسندگان
چکیده
BACKGROUND Eggcrate upper-room ultraviolet germicidal irradiation (UVGI), an engineering control method for reducing the airborne transmission of infectious diseases, was recently developed as an alternative to conventional upper-room UVGI using conventional louvered fixtures. A UV screen, which is composed of open-cell eggcrate panels supported in a frame designed for a conventional suspended ceiling, was used to minimize UV radiation in the lower room. A ceiling fan, which was blowing upward directly above the microbiological source, provided vertical air exchange between the upper and lower room. This system has been shown to be significantly more effective than conventional upper-room UVGI. STUDY DESIGN In the present study, the microbiological source location and the airflow direction due to the ceiling fan were varied in order to evaluate their impact on germicidal efficacy. RESULTS The test results clearly showed that placing an aerosol source directly underneath an upward blowing ceiling fan produces the maximum efficacy. CONCLUSIONS The likely explanation for this outcome is that the fan sucks the microorganisms emitted by the source into the UV beam before being mixed with the air in the room. This is somewhat analogous to local exhaust ventilation in which the contaminant is removed prior to being mixed with the air in the room. Thus, when possible, the ceiling fan should be blowing upward and directly above the source. However, for experimental testing, the source location should be varied in order to access the range of germicidal efficacies that can be expected.
منابع مشابه
The characterization of upper-room ultraviolet germicidal irradiation in inactivating airborne microorganisms.
In this study, we explored the efficacy of upper-room ultraviolet germicidal irradiation (UVGI) in reducing the concentration of Serratia marcescens and Mycobacterium bovis bacille Calmette-Guérin (BCG) aerosols in enclosed places. We constructed a facility (4.5 m x 3 m x 2.9 m) in which both ceiling- and wall-mounted UV fixtures (UV output: 10W and 5W respectively) were installed. The use of c...
متن کاملA Case Study of Upper-Room UVGI in Densely-Occupied Elementary Classrooms by Real-Time Fluorescent Bioaerosol Measurements
Recently, the requirement to continuously collect bioaerosol samples using shorter response times has called for the use of real-time detection. The decreased cost of this technology makes it available for a wider application than military use, and makes it accessible to pharmaceutical and academic research. In this case study, real-time bioaerosol monitors (RBMs) were applied in elementary sch...
متن کاملStudent absenteeism and the comparisons of two sampling procedures for culturable bioaerosol measurement in classrooms with and without upper room ultraviolet germicidal irradiation devices
Upper room ultraviolet germicidal irradiance (UVGI) has been shown to reduce the concentration of bioaerosols in controlled chambers. However, there is a lack of experimental results on the reduction of bioaerosol concentrations by UVGI devices in actual uncontrolled buildings. This study was carried out in an American elementary school in the Midwest. Two sampling procedures were carried out i...
متن کاملMinimizing the exposure of airborne pathogens by upper-room ultraviolet germicidal irradiation: an experimental and numerical study.
There has been increasing interest in the use of upper-room ultraviolet germicidal irradiation (UVGI) because of its proven effectiveness in disinfecting airborne pathogens. An improved drift flux mathematical model is developed for optimizing the design of indoor upper-room UVGI systems by predicting the distribution and inactivation of bioaerosols in a ventilation room equipped with a UVGI sy...
متن کاملMonitoring human exposures to upper-room germicidal ultraviolet irradiation.
After decades of neglect, the resurgence of tuberculosis in the United States between 1985 and 1992 renewed interest in the use of upper room ultraviolet germicidal irradiation to interrupt the transmission of airborne infections. More recently the bioterrorism threat and the appearance of new pathogens with the potential for airborne spread, such as severe acute respiratory syndrome (SARS), ha...
متن کامل