Radiopacity of root filling materials using digital radiography.

نویسندگان

  • J R Carvalho-Junior
  • L Correr-Sobrinho
  • A B Correr
  • M A C Sinhoreti
  • S Consani
  • M D Sousa-Neto
چکیده

AIM To evaluate radiopacity of root filling materials using digital radiography. METHODOLOGY The sealers tested were AH Plus, Endofill, EndoREZ and Epiphany. Gutta-percha (Dentsply Maillefer) and Resilon cones were also tested. Acrylic plates, containing six wells, measuring 1 mm in depth and 5 mm in diameter, were prepared for the test, and filled with the materials. The test samples were radiographed together with an aluminium stepwedge calibrated in millimetres, according to ANSI/ADA Specification 57. For the radiographic exposures, digital imaging plates and an X-ray machine at 70 kVp and 8 mA were used. The object-to-focus distance was 30 cm, and the exposure time, 0.2 s. After the laser optic reading process, the software determined the radiopacity of the standardized areas, using grey-scale values, calculating the average radiographic density for each material. RESULTS The decreasing values of radiopacity of the studied materials, expressed in millimetres of aluminium equivalent, were: Resilon (13.0), AH Plus(TM) (11.2), gutta-percha (9.8), Epiphany (8.0), Endofill (6.9) and EndoREZ (6.6). CONCLUSION All materials had radiopacity values above 3 mm of aluminium recommended by ANSI/ADA Specification 57.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative radiographic assessment of a new bioceramic-based root canal sealer

BACKGROUND AND AIMS The aim of this study was to assess the radiopacity of two bioceramic-based root canal sealers, the conventional TotalFill BC sealer (FKG Dentaire Switzerland) and a new experimental filling material developed in collaboration with 'Raluca Ripan' Institute for Research in Chemistry, Cluj-Napoca. METHODS Five disc samples were prepared using both materials (10 mm diameter ×...

متن کامل

Comparative study of digital radiopacity of dental cements

Introduction: Radiopacity is a necessary property for luting cements . The aim of this study was to investigate the radiopacity of some luting dental cements used in prosthetic dentistry. Methods: Five disclike samples of each material (6 x 1 mm) were prepared from panavia F2.0(Pa), Chioce2 (Ch.2), Glass ionomer GC (GI GC), zinc phosphate Hoffmann’s (ZP hof), zinc polycarboxylate Hoffm...

متن کامل

Radiopacity Evaluation of Root-end Filling Materials by Digitization of Images

The purpose of this study was to evaluate the radiopacity of 5 root-end filling materials (white MTA-Angelus, grey MTA-Angelus, IRM, Super EBA and Sealer 26). Five specimens (10 mm diameter X 1 mm thickness) were made from each material and radiographed next to an aluminum stepwedge varying in thickness from 2 to 16 mm. Radiographs were digitized and the radiopacity of the materials was compare...

متن کامل

Comparison of Radiopacity of Six Endodontic Sealers

Introduction: Optimal radiopacity is one of the properties required for a root canal sealer that helps the distinction between the sealer and surrounding anatomic structures and evaluation of the quality of root filling. So, the purpose of this study was to evaluate the radiopacity of six root canal sealers at different focal distances. Materials and Methods: In this in vitro study, six endodo...

متن کامل

Evaluation of the Radiopacity of Some Luting, Lining and Filling Dental Cements

Background and Aim: To investigate the radiopacity of different luting, lining and filling dental cements used in prosthetic dentistry in comparison with human and bovine dental hard tissues. Material and methods: Eight cylindrical samples of each material (6 x 1 mm) were prepared from Aqualox (APC), Durelon (DE) and Adhesor Carbofine (ACF) zinc polycarboxylate cements, Cavex zinc oxide eugenol...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International endodontic journal

دوره 40 7  شماره 

صفحات  -

تاریخ انتشار 2007