Implant breakage, a rare complication with the Gamma nail. A review of 843 fractures of the proximal femur treated with a Gamma nail.
نویسندگان
چکیده
Internal fixation with a Gamma nail, in its short and long versions, is an excellent surgical technique for intertrochanteric and subtrochanteric fractures of the femur. A stable osteosynthesis is obtained which allows early mobilisation and promotes healing of the fracture. However, it is not free from complications; many of them are due to poor surgical technique and/or inadequate monitoring. Breakage due to fatigue of the material is an exceptional complication. A review of 843 cases operated in our department between 1990 and 2002 was made. Five cases of implant breakage were found. Non-union of the fracture appears to be the primary cause. The weakest point of the Gamma nail is the opening for the cervical screw. The optimal treatment will depend on each particular case. The possibility of dynamisation of the construct should be considered when delayed healing is suspected.
منابع مشابه
Breakage of a Third Generation Gamma Nail: A Case Report and Review of the Literature
The use of intramedullary nails to treat trochanteric fractures of the femur has increased with the increasing size of the elderly population. The third generation Gamma nail is currently one of the most popular devices for the treatment of trochanteric fractures. Nail breakage is a rare complication, possibly resulting from fatigue fracture of the implant. We present the first reported case of...
متن کاملGamma nail breakage: a report of four cases.
Gamma nails have been used extensively for the treatment of proximal femoral fractures. Nail breakage at the level of the aperture of the lag screw is rare. We report 4 such cases mainly associated with a large posteromedial cortex gap and nonunion. The need for adequate reduction to avoid such a complication is emphasised.
متن کاملThe Long Gamma Nail for stabilisation of existing and impending pathological fractures of the femur: an analysis of 48 cases.
The results in a series of 42 patients with 48 impending or complete pathological femur fractures stabilised with the Long Gamma nail (Howmedica-Osteonics, Rutherford, NJ,USA) are presented. Twenty two impending and 26 completed pathological femoral fractures treated between 1995 and 1999 were retrospectively analysed. The mean age of the patients was 65.7 yrs (range: 40 to 88). All patients we...
متن کاملProximal femoral nail antirotation and third-generation Gamma nail: which is a better device for the treatment of intertrochanteric fractures?
INTRODUCTION Proximal femoral nail antirotation (PFNA) and third-generation Gamma nail (Gamma 3) are widely used in the treatment of intertrochanteric fractures. However, it remains unclear which device achieves better clinical and radiographic outcomes when treating intertrochanteric fractures. METHODS This study comprised 239 patients with intertrochanteric fractures treated with either PFN...
متن کاملBiomechanical comparison of dynamic hip screw and Gamma nail for the treatment of unstable trochanteric fractures: a finite element study
Objectives: To investigate the biomechanical behavior of the femur with two different implant configurations, namely dynamic hip screw and Gamma nail, in the treatment of two types of unstable intertrochanteric femoral fracture. Methods: A 3D finite element model of the intact proximal femur was constructed, from which two types of fractured models (AO classification 31-A2 and 31-A3) were produ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta orthopaedica Belgica
دوره 70 5 شماره
صفحات -
تاریخ انتشار 2004