6-Plex microsphere immunoassay with imaging planar array detection for mycotoxins in barley.
نویسندگان
چکیده
Mycotoxins are produced by fungi as secondary metabolites. They often multi-contaminate food and feed commodities posing a health risk to humans and animals. A fast and easy to apply multiplex screening of these commodities could be useful to detect multi-contamination. For this, we developed a semi-quantitative 6-plex immunoassay using a suspension array of paramagnetic colour-coded microspheres combined with imaging planar array detection for the mycotoxins aflatoxin B1, ochratoxin A, zearalenone, deoxynivalenol, T2-toxin, HT-2 toxin and fumonisin B1. Mycotoxin specific monoclonal antibodies were coupled to different sets of microspheres and mycotoxins conjugated to the fluorescent protein R-phycoerythrin served as reporter molecules. Competition between free mycotoxins in the sample and mixed reporter molecules for antibody binding sites on mixed microspheres created a multiplex direct inhibition immunoassay. The reagents were selected for no or low cross-interactions between the assays and cross-reactions with metabolites and possible masked forms were determined. A within-laboratory validation was carried out using blank and spiked barley samples. Furthermore, the 6-plex was used to screen available barley, and malted barley, reference materials. The validation showed very high inter and intra-day precision for all samples with a maximum relative standard deviation value of 10%. The screening assay allows easy and rapid multiplex detection of the target mycotoxins in barley according to EU legislation. With a cut off factor of 50%, based on the EU maximum levels, we were able to screen at 2 μg kg(-1) for aflatoxin B1, 2.5 μg kg(-1) for ochratoxin A, 625 μg kg(-1) for deoxynivalenol, 50 μg kg(-1) for zearalenone, 1000 μg kg(-1) for fumonisin B1 and 25 μg kg(-1) for T-2 toxin. Thanks to the transportable planar array system, the developed 6-plex has potential for future on-site testing. Future implementation of this method as a pre-screening tool, prior to instrumental analysis, is highly attractive since costly LC-MS/MS analysis of samples below the maximum levels can be avoided.
منابع مشابه
Multiplex surface plasmon resonance biosensing and its transferability towards imaging nanoplasmonics for detection of mycotoxins in barley.
A 6-plex competitive inhibition immunoassay for mycotoxins in barley was developed on a prototype portable nanostructured imaging surface plasmon resonance (iSPR) instrument, also referred to as imaging nanoplasmonics. As a benchmark for the prototype nanoplasmonics instrument, first a double 3-plex assay was developed for the detection of deoxynivalenol (DON), zearalenone (ZEA), T-2 toxin (T-2...
متن کاملA Multiplex Microsphere-Based Immunoassay Increases the Sensitivity of SIV-Specific Antibody Detection in Serum Samples and Mucosal Specimens Collected from Rhesus Macaques Infected with SIVmac239
Results from recent HIV-1 vaccine studies have indicated that high serum antibody (Ab) titers may not be necessary for Ab-mediated protection, and that Abs localized to mucosal sites might be critical for preventing infection. Enzyme-linked immunosorbent assay (ELISA) has been used for decades as the gold standard for Ab measurement, though recently, highly sensitive microsphere-based assays ha...
متن کاملPhased array ultrasonic imaging using an improved beamforming based total focusing method for non destructive test
One of the novel ultrasonic phased array based scanning methods for ultrasonic imaging in non-destructive test is total focusing method (TFM). This method employs maximum available information of the phased array elements and leads to an improved defect detection accuracy compared to conventional scanning methods. Despite its high detection accuracy, TFM behaves weak in distinguishing the real ...
متن کاملPhased array ultrasonic imaging using an improved beamforming based total focusing method for non destructive test
One of the novel ultrasonic phased array based scanning methods for ultrasonic imaging in non-destructive test is total focusing method (TFM). This method employs maximum available information of the phased array elements and leads to an improved defect detection accuracy compared to conventional scanning methods. Despite its high detection accuracy, TFM behaves weak in distinguishing the real ...
متن کاملComparison of multiplex immunoassay platforms.
BACKGROUND Candidate biomarkers discovered with high-throughput proteomic techniques (along with many biomarkers reported in the literature) must be rigorously validated. The simultaneous quantitative assessment of multiple potential biomarkers across large cohorts presents a major challenge to the field. Multiplex immunoassays represent a promising solution, with the potential to provide quant...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Analyst
دوره 139 16 شماره
صفحات -
تاریخ انتشار 2014