Aortic root dynamics are asymmetric.

نویسندگان

  • Emmanuel Lansac
  • Hou-Sen Lim
  • Yu Shomura
  • Khee Hiang Lim
  • Nolan T Rice
  • Wolfgang A Goetz
  • Carlos M G Duran
چکیده

BACKGROUND AND AIM OF THE STUDY The presence of conformational changes in the aortic root during the cardiac cycle is well known, but precise information on time-related changes at each level of the root is lacking. METHODS High-resolution, 3D sonomicrometry (200 Hz) was applied in an acute sheep model. Twelve crystals were implanted in eight sheep at each base (n = 3), commissure (n = 3), sinotubular junction (n = 3) and ascending aorta (n = 3). Under stable hemodynamic conditions, geometric changes of the perimeter of each sinus of Valsalva, sinus height, and twist and root tilt angles were time-related to left ventricluar (LV) and aortic pressures. RESULTS Expansion of the perimeter of the three sinuses of Valsalva was homogeneous, but in significantly different proportions (p < 0.001): the right sinus expanded (+32.4 +/- 2.4%) more than the left (+29.3 +/- 3.2%), and more than the non-coronary (NC) sinus (+25.8 +/- 1.7%). A similar pattern was found for aortic root height: right greater than left, and left greater than NC sinus (p < 0.001). This asymmetry resulted in changes of the root's twist and tilt angles. Although the twist deformation was consistent for each sheep, no general pattern was found. The aortic root tilt angle (between the basal plane and the commissural plane) was 16.3 +/- 1.5 degrees at end-diastole (angle oriented posteriorly and to the left). During systole, it was reduced by 6.6 +/- 0.5 degrees, aligning the LV outflow tract with the ascending aorta. This tilt angle returned to its original value after valve closure. CONCLUSION Aortic root expansion is asymmetric, generating precise changes in its tilt angle. During systole, tilt angle reduction resulted in a straight cylinder that probably facilitates ejection; during diastole, the tilt angle increased, probably reducing leaflet stress. These findings should impact upon surgical procedures and the design of new prostheses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Deformational dynamics of the aortic root: modes and physiologic determinants.

BACKGROUND Current surgical methods for treating aortic valve and aortic root pathology vary widely, and the basis for selecting one repair or replacement alternative over another continues to evolve. More precise knowledge of the interaction between normal aortic root dynamics and aortic valve mechanics may clarify the implications of various surgical procedures on long-term valve function and...

متن کامل

The wide spectrum of aortic root dilatation after the Ross operation

INTRODUCTION The Ross root replacement is the only technique that guarantees long-term viability of all the component parts of the root. The normal aortic root performs extremely sophisticated functions which are closely linked to its structure, dynamics and viability. This has been shown to translate into clinically-relevant endpoints, such as survival and quality of life. The insertion of the...

متن کامل

Aortic root dynamics and surgery: from craft to science.

Since the fifteenth century beginning with Leonardo da Vinci's studies, the precise structure and functional dynamics of the aortic root throughout the cardiac cycle continues to elude investigators. The last five decades of experimental work have contributed substantially to our current understanding of aortic root dynamics. In this article, we review and summarize the relevant structural anal...

متن کامل

Including Residual Stress and Initial Strain in an Asymmetric Model of the Aortic Root !

! The aortic root is the group of structures that make up the aortic valve. Besides the aortic leaflets, the aortic root complex includes the aortic annulus, the Valsalva sinuses, and the sinotubolar junction [1]. This group of structures has the functional role of assisting valve opening and closure by creating and maintaining the optimal pressure difference between the aorta and the left vent...

متن کامل

Effects of asymmetric stiffness on parametric instabilities of rotor

This work deals with effects of asymmetric stiffness on the dynamic behaviour of the rotor system. The analysis is presented through an extended Lagrangian Hamiltonian mechanics on the asymmetric rotor system, where symmetries are broken in terms of the rotor stiffness. The complete dynamics of asymmetries of rotor system is investigated with a case study. In this work, a mathematical model is ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of heart valve disease

دوره 14 3  شماره 

صفحات  -

تاریخ انتشار 2005