Emg Amplitude Estimation Using Adaptive Whitening

نویسنده

  • Edward A. Clancy
چکیده

4.35k1.86 15.48f3.21 Abstract Previous research showed that whitening the surface electromyogram (EMC) can improve EMG amplitude estimation. However, conventional linear-filter whitening fails at low EMG amplitude levels, perhaps due to additive background noise in the measured EMG signal. This paper describes an adaptive whitening technique, effective at low EMG levels, that cascades a non-adaptive whitening filter, an adaptive Wiener filter, and an adaptive gain correction. In experimental studies, subjects used real-time EMG amplitude estimates to track a uniform-density, band-limited random target. With a 0.25 Hz bandwidth target, either adaptive whitening or multi-channel processing reduced the tracking error to roughly half that of using force as the feedback signal. Increases in additive noise level, smoothing window length, and tracking bandwidth diminish the advantages of adaptive whitening.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation and application of EMG amplitude during dynamic contractions.

The sections above have described an EMG amplitude estimator and an initial application of this estimator to the EMG-torque problem. The amplitude estimator consists of six stages. In the first stage, motion artifact and power-line interference are attenuated. Motion artifact is typically removed with a highpass filter. Elimination of power-line noise is more difficult. Commercial systems tend ...

متن کامل

Emg Amplitude Estimation: a Review of the past and a Look towards the Future

AND INTRODUCTION The amplitude of the surfa.ce EMG is frequently used as the control input to myoelectric prostheses, as a measure of muscular effort, and has also been investigated as an indicator of muscle force This paper will review the methods which are used to estimate the EMG amplitude from recordings of the EMG waveform. (Note that this review does not include the related area of EMG-to...

متن کامل

Sampling, noise-reduction and amplitude estimation issues in surface electromyography.

This paper reviews data acquisition and signal processing issues relative to producing an amplitude estimate of surface EMG. The paper covers two principle areas. First, methods for reducing noise, artefact and interference in recorded EMG are described. Wherever possible noise should be reduced at the source via appropriate skin preparation, and the use of well designed active electrodes and s...

متن کامل

Effect of Smoothing Window Length on RMS EMG Amplitude Estimates - Bioengineering Conference, 1996., Proceedings of the 1996 IEEE Twenty-Second Annual Northeast

This paper describes the results of a study on the influence of smoothing window length on the signal-to-noise ratio (SNR) of electromyogram (EMG) amplitude estimates. In a previous experiment, surface EMG waveforms were recorded for non-fatiguing, constant-force, isometric contraction of the biceps and triceps muscles. Based on these data, four different EMG processors were studied using smoot...

متن کامل

A Simulation Study of Unwhitened Versus Whitened EMG Amplitude Estimation - Bioengineering Conference, 1997., Proceedings of the IEEE 1997 23rd Northeast

Amplitude estimates of simulated surface electromyograms (EMGs) were studied using both unwhitened and whitened EMG amplitude estimators. Constant-effort non-fatiguing EMGs were simulated as the superposition of simple synthetic motor unit action potential trains (MUAPTs). Each MUAPT was formed from random firings of randomly shaped motor unit action potentials. Two aspects of unwhitened vs. wh...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004