Repetitive stent fractures with diffuse coronary artery microaneurysm formation--sirolimus eluting stent hypersensitivity?
نویسندگان
چکیده
While drug eluting stents (DES) are being more widely used in ever more patients receiving DES each day, some new complications may be emerging. Stent fractures and hypersensitivity reactions to stents are among recognized complications that can lead to therapeutic dead end from the interventional cardiologist's point of view. We present a case in which we reached therapeutic dead end with a sirolimus eluting stent, i.e. repetitive stent fractures with diffuse microaneurysms along the implanted DES, possibly due to hypersensitivity reaction to parts of the stent.
منابع مشابه
Late multiple stent fractures following deployment of sirolimus-eluting stents for diffuse right coronary artery stenosis.
We report a case of late multiple stent fractures following the deployment of sirolimus-eluting stents (SESs) for diffuse right coronary artery (RCA) stenosis. A 44-year-old male with hyperlipidemia was referred to our hospital for acute myocardial infarction (AMI). Percutaneous coronary intervention (PCI) was performed for total occlusion of the proximal segment of the RCA, and 5 SESs were con...
متن کاملنتایج بالینی پس از آنژیوپلاستی عروق کرونر، بروز حوادث بزرگ قلبی-عروقی و عوارض انواع استنت
Background: Cardiovascular diseases alone have become the leading cause of death worldwide. One of the treatment methods cardiovascular disease is angioplasty. This study aimed to investigate the clinical results after coronary artery angioplasty, based on the incidence of major cardiovascular events with emphasis on stent types. Methods: In this retrospective cross-sectional study, the preval...
متن کاملComplete Fracture of Sirolimus-Eluting Stent in a Saphenous Vein Graft to Left Anterior Descending Artery
Coronary stent fractures have been suggested as a potential new mechanism of restenosis. The mechanical properties of stents were designed not only to prevent vessel recoil, but also to resist the mechanical stress of vessel movement over millions of cardiac cycles. We present a case in which mechanical stress may have contributed to the fracture of a stent implanted in a saphenous vein graft (...
متن کاملDouble coronary artery stent fracture with coronary artery microaneurysms.
Even though drug-eluting stent (DES) implantation is an effective treatment for coronary artery stenosis, there are growing concerns related to the real usefulness of DESs due to their increased incidence of thrombosis, stent fracture, and late stent malapposition in comparison to bare metal stents. We have previously reported a case of stent fractures and multiple microaneurysms in both the le...
متن کاملOverview of Intracoronary Brachytherapy for in-Stent Restenosis of a Drug-Eluting Stent
Percutaneous coronary intervention with stenting is considered recently as the most common procedure for the treatment of symptomatic coronary. The article reviewed 41 studies published during 1997-2019 on intracoronary brachytherapy for in-stent restenosis of a drug-eluting stent. Intracoronary radiation therapy was finally confirmed in the setting of in-stent restenosis using as adjunctive th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta clinica Croatica
دوره 50 4 شماره
صفحات -
تاریخ انتشار 2011