The cementless PM hip arthroplasty. Four-to-seven-year results.

نویسندگان

  • M Dickob
  • T Martini
چکیده

We implanted 300 uncoated cementless PM prostheses into 271 patients and followed 251 (92.6%) of them for four to seven years. By then 37 had already been revised for aseptic and three for septic loosening. The survival rate with implant failure as the endpoint was 88.8% for the cup and 85.3% for the stem after six years. There was a higher risk of implant loosening in congenital dysplasia, unilateral hip arthroplasty and obesity. The results of 225 unrevised hip replacements were assessed by questionnaire. Only 27.4% of the patients were completely free from pain and 17.9% had pain on walking any distance or at all times. The walking distance was for less than 30 minutes in 40%. Because of the poor results in comparison with other prostheses we do not recommend further use of the uncoated PM prosthesis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cementless Total Hip Arthroplasty After an Iatrogenic Subtrochanteric Fracture due to Hardware Removal: A Case Report

Introduction: Total hip arthroplasty (THA) after proximal femoral fixation is a challenging procedure due to possible hardware-related complications. Case presentation: A 78-year-old female with hip osteoarthritis had a proximal femoral osteotomy fixed using a blade plate in the same femur 41 years ago. A two-step approach was planned. After a challenging...

متن کامل

Cementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs

Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations.Methods: 52 primary cementless total hip arthroplasty in...

متن کامل

Minimum Seven-year Follow-up of Cementless Total Hip Arthroplasty with the COREN Hip System

Total hip arthroplasty (THA) is currently one of the most widely performed procedures in orthopedic practice. Over recent years, THA gained much improvement in terms of prosthesis design, availability of suitable component materials and manufacturing techniques, and a better understanding of hip mechanics. In a previous study, we reported results at a mean 3.2 years following implantation of th...

متن کامل

Primary total hip arthroplasty without the use of bone cement: a 10-year follow-up of 157 hips.

BACKGROUND The cementless fixation technique in total hip arthroplasty (THA) was developed to solve clinical problems such as aseptic loosening and osteolysis which were thought to be associated with the use of bone cement. This retrospective study reports our mid-term results with cementless THA. METHODS A series of 173 consecutive, unselected cementless THA procedures using the Omnifit pros...

متن کامل

Acetabular components in total hip arthroplasty: is there evidence that cementless fixation is better?

BACKGROUND The use of cementless acetabular components in total hip arthroplasty has gained popularity over the past decade. Most total hip arthroplasties being performed in North America currently use cementless acetabular components. The objective of this systematic review and meta-analysis was to compare the survivorship and revision rate of cemented and cementless acetabular components util...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 78 2  شماره 

صفحات  -

تاریخ انتشار 1996