Hemodynamics of human carotid artery bifurcations: computational studies with models reconstructed from magnetic resonance imaging of normal subjects.
نویسندگان
چکیده
PURPOSE The precise role played by hemodynamics, particularly wall shear stress, in the development and progression of vascular disease remains unclear, in large part because of a lack of in vivo studies with humans. Although technical challenges remain for noninvasively imaging wall shear stresses in humans, vascular anatomy can be imaged with sufficiently high resolution to allow reconstruction of three-dimensional models for computational hemodynamic studies. In this paper we present an entirely noninvasive magnetic resonance imaging (MRI) protocol that provides carotid bifurcation geometry and flow rates from which the in vivo hemodynamics can be computed. Maps of average, oscillatory, and gradients of wall shear stress are presented for two normal human subjects, and their data are compared with those computed for an idealized carotid bifurcation model. METHODS An MRI protocol was developed to acquire all necessary image data in scan times suitable for patient studies. Three-dimensional models of the carotid bifurcation lumen were reconstructed from serial black blood MR images of two normal volunteers. Common and internal carotid artery flow rate waveforms were determined from MRI phase-contrast velocity imaging in the same subjects and were used to impose fully developed velocity boundary conditions for the computational model. Subject-specific time-resolved velocities and wall shear stresses were then computed with a finite element-based Navier-Stokes equation solver. RESULTS Models reconstructed from in vivo MRI of two subjects showed obvious differences in branch angle, bulb size and extent, and three-dimensional curvature. Maps of a variety of wall shear stress indices showed obvious qualitative differences in patterns between the in vivo models and between the in vivo models and the idealized model. Secondary, helical flow patterns, induced primarily by the asymmetric and curved in vivo geometries, were found to play a key role in determining the resulting wall shear stress patterns. The use of in vivo flow rate waveforms was found to play a minor but noticeable role in some of the wall shear stress behavior observed. CONCLUSIONS Conventional "averaged" carotid bifurcation models mask interesting hemodynamic features observed in realistic models derived from noninvasive imaging of normal human subjects. Observation of intersubject variations in the in vivo wall shear stress patterns supports the notion that more conclusive evidence regarding the role of hemodynamics in vascular disease may be derived from such individual studies. The techniques presented here, when combined with subject-specific MRI measurements of carotid artery plaque thickness and composition, provide the tools necessary for entirely noninvasive, prospective, in vivo human studies of hemodynamics and the relationship of hemodynamics to vascular disease.
منابع مشابه
Reconstruction of carotid bifurcation hemodynamics and wall thickness using computational fluid dynamics and MRI.
A thorough understanding of the relationship between local hemodynamics and plaque progression has been hindered by an inability to prospectively monitor these factors in vivo in humans. In this study a novel approach for noninvasively reconstructing artery wall thickness and local hemodynamics at the human carotid bifurcation is presented. Three-dimensional (3D) models of the lumen and wall bo...
متن کاملGeometric Characterization of the Normal and Mildly Diseased Human Carotid Bifurcation
INTRODUCTION The geometry of the carotid bifurcation has been proposed as a possible risk factor for atherosclerosis, by virtue of the purported role of local hemodynamics in early stages of atherosclerotic plaque development [1]. In this context it is of interest to study asymptomatic subjects with mild carotid artery disease. Instead, investigations of carotid bifurcation geometry and hemodyn...
متن کاملNew Methods for Computational Fluid Dynamics Modeling of Carotid Artery from Magnetic Resonance Angiography
Computational fluid dynamics (CFD) models of the carotid artery are constructed from contrast-enhanced magnetic resonance angiography (MRA) using a deformable model and a surface-merging algorithm. Physiologic flow conditions are obtained from cine phase-contrast MRA at two slice locations below and above the carotid bifurcation. The methodology was tested on image data from a rigid flow-throug...
متن کاملNumerical Modelling of the Diseased Carotid Artery Bifurcation Using a Physiologically Relevant Geometric Model
Atherosclerosis is a disease that is characterized by the hardening and thickening of the arterial walls due to the formation of plaque. As this disease progresses, the formation of plaque reduces the arterial passage area creating uncharacteristic blood flow patterns. As a result, this restriction, if severe enough, can cause individuals to suffer cardiac arrest or stroke. Also, small pieces o...
متن کاملDistensibility measurements along carotid atherosclerotic plaques: how can we improve the mechanical modeling of atherosclerosis?
Motivation Biomechanical modeling of atherosclerotic plaques is emerging as a useful tool to provide markers of plaque vulnerability. However, the success of this modeling effort depends on the accurate estimation of local mechanical properties along the diseased vessel wall. Recent studies in healthy carotid bifurcations reported differences in wall distensibility between common and internal c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of vascular surgery
دوره 28 1 شماره
صفحات -
تاریخ انتشار 1998