Clinical strategies to reduce utilization of chest physiotherapy without compromising patient care.

نویسندگان

  • E Alexander
  • S Weingarten
  • Z Mohsenifar
چکیده

BACKGROUND There is widespread interest in the evaluation of clinical strategies that safely reduce health-care costs. Elimination of inappropriate chest physiotherapy may represent one of those strategies. SETTING An academic community hospital. METHODS One-hundred one patients receiving chest physiotherapy were prospectively randomized to continue their chest physiotherapy or to inform their physicians that the order for the chest physiotherapy may have been inappropriate. RESULTS Patients who were randomized to have their chest physiotherapy discontinued received 45% fewer chest physiotherapy treatments than control patients (p < 0.01). There was no increase in the mortality rate or length of hospital stay associated with the reduction in chest physiotherapy in carefully selected patients. The estimated cost savings would be $319,000, which is 50 times greater than the cost associated with the intervention. CONCLUSION Chest physiotherapy is frequently provided to patients for inappropriate indications. Reducing chest physiotherapy for these patients may significantly reduce respiratory therapy costs without increasing length of stay or mortality rates.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pulmonary Rehabilitation and Physiotherapy Management of Respiratory Conditions in Patient with COVID-19: Narrative Review

Introduction: COVID-19 is a disease caused by a novel type of coronavirus which primarily affects the respiratory system , induces mild pulmonary symptoms (e.g cough and dyspnea), is easily recovered and causes pneumonia in severe cases. It gets to admit the patientsin the intensive care unit. Physiotherapy and pulmonary rehabilitation play an important role in improving respiratory function an...

متن کامل

A study protocol of a randomised controlled trial incorporating a health economic analysis to investigate if additional allied health services for rehabilitation reduce length of stay without compromising patient outcomes

BACKGROUND Reducing patient length of stay is a high priority for health service providers. Preliminary information suggests additional Saturday rehabilitation services could reduce the time a patient stays in hospital by three days. This large trial will examine if providing additional physiotherapy and occupational therapy services on a Saturday reduces health care costs, and improves the hea...

متن کامل

Utilization and out of pocket (OOP) payment for physiotherapy services in public hospitals of Shahid Beheshti University of Medical Sciences

Background: Physiotherapy services constitute a principle part of health care systems, and interest in their use has increased in the recent decades.&nbsp; This study was conducted to investigate the utilization and OOP payment for physiotherapy services in public hospitals of Shahid Beheshti University of Medical Sciences in Tehran, Iran. &nbsp;&nbsp; Methods: This cross-sectional study was c...

متن کامل

Strategies for the Prevention of Ventilator-associated Pneumonia in the Intensive Care Units: A Review

Ventilator-Associated Pneumonia (VAP) accounts for 80%-90% of hospital-acquired pneumonia cases in Intensive Care Units (ICUs). VAP occurs 48-72 hours after intubation, and is observed in 27%-29% of patients with endotracheal tube, and its risk increases with the increase in the duration of mechanical ventilation. In this review study, papers published from 1996-2018 were used to investigate st...

متن کامل

A Phantom Study for the Optimization of Image Quality and Radiation Dose for Common Radiographic Examinations in Digital Radiography

Introduction: Phantom studies facilitate the implementation of radiation dose surveillance as a function of radiographic technical parameters for minimizing patient radiation dose. The evidence of such investigations can then be used to evaluate technical parameters used in the radiographic procedures to reduce radiation dose without compromising the image quality. Material and Methods: This ex...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 110 2  شماره 

صفحات  -

تاریخ انتشار 1996