Patient doses from medical examinations in Russia: 2009-2015.
نویسندگان
چکیده
The aim of this study was to evaluate adult patient doses in Russia in the context of patient protection. Effective doses from x-ray and nuclear medicine examinations were assessed using two approaches. The first was based on data collection performed by the authors in hospitals in St. Petersburg and other 17 Russian regions. The second approach was to assess mean doses through the collective dose estimated annually within the federal data bank ESKID. In 2015, 203 million examinations were conducted in Russia, i.e. 1.4 examinations per capita. The number of examinations has increased by 35% over the last 10 years. Patient doses from x-ray examinations are strongly dependent on the imaging modality. Mean dose increases by an order of magnitude with each x-ray modality from dental examinations (0.01-0.1 mSv) to radiography (0.1-1 mSv), fluoroscopy and CT (1-10 mSv) and to interventional examinations (more than 10 mSv). Mean doses for x-ray examinations are comparable with that of foreign countries. Scintigraphy examinations with 99mTc are associated with mean doses of 1-5 mSv. Mean doses from PET/CT whole body examinations are 15-25 mSv with similar contributions from CT and radiopharmaceuticals. In nuclear medicine, patient doses are lower compared to other countries. According to ESKID data the collective dose from medical exposure in Russia has decreased from 140 000 man-Sv in 2000 to 77 000 man-Sv in 2015. Medical exposure contributes about 13% into a total collective dose. The maximum contribution was from CT examinations, i.e. 45% in 2015. A range of mean doses between different hospitals was up to two orders of magnitude for radiography and one order of magnitude for CT. In interventional studies, the scatter of individual doses was significant. Significant variations in doses between hospitals and some regions indicate the potential for optimization with the focus on interventional examinations, CT and nuclear medicine examinations combined with CT.
منابع مشابه
Evaluation of Organ and Effective Doses to Patients Arising From Some Common X-Ray Examinations by PCXMC Program in Sabzevar, Iran
Introduction The purpose of this study was to estimate organ and effective doses in patients undergoing some common X-ray examinations in Sabzevar, Iran. The effective dose is one of the best parameters for describing the amount of radiation dose received by a patient undergoing any diagnostic X-ray examination. The public dose from X-ray examinations depends on various factors, and its contrib...
متن کاملPatient doses from X-ray computed tomography examinations by a single-array detector unit: Axial versus spiral mode
Background: X-ray computed tomography (CT) examinations deliver a significant amount of radiation doses to patients comparing to conventional radiography examinations. The objective of the current study was to analyze and investigate the average patient received dose from axial and spiral CT exams in a medical imaging center. Material and Methods: In this study, the patient imaging tec...
متن کاملAssessment of patient entrance skin dose (ESD) and effective dose (ED) for the most common interventional radiological exams at Mazandaran hospital
Introduction: Nowadays we are witnessing an exponential application of interventional radiology techniques in various communities as well as Iran. Radiological technique is regarded as the 2nd contributing factor in increasing the amount of public doses in various societies. So that related radiation protection organization has recommended measuring patient d...
متن کاملAssessment of patients’ entrance skin and effective dose in a mathematical human phantom for the most common interventional radiological examinations
Introduction: Nowadays, we are witnessing an exponential use of interventional radiology techniques in different communities. After CT, interventional techniques are the second factor of increasing patients’ doses in different societies. Measuring patient doses from aforementioned methods has been recommended by many radiation protection professional organizations such as ICRP...
متن کاملPatient effective dose estimation for routine computed tomography examinations in Iran
Background: The present study intended to determine and report patient effective dose on the basis of patients and exposure data. Materials and methods: A nationwide computed tomography (CT) survey was provided as a report of patient doses in 2015-2016. Scan details were collected for nearly 2,000 adults and children in four age groups subjected to CT examinations. From total 565 CT scanners in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of radiological protection : official journal of the Society for Radiological Protection
دوره 38 1 شماره
صفحات -
تاریخ انتشار 2018