Long term changes in the upper stratospheric ozone at Syowa, Antarctica

نویسنده

  • K. Miyagawa
چکیده

Analyses of stratospheric ozone data determined from Dobson–Umkehr measurements since 1977 at the Syowa (69.0 S, 39.6 E), Antarctica, station show a significant decrease in ozone at altitudes higher than that of the 4 hPa pressure level during the 1980s and 1990s. Ozone values over Syowa have remained low since 2001. The time series of upper stratospheric ozone from the homogenized NOAA SBUV (Solar Backscatter Ultraviolet Instrument)(/2) 8.6 overpass data (±4, 24 h) are in qualitative agreement with those from the Syowa station data. Ozone recovery during the austral spring over the Syowa station appears to be slower than predicted by the equivalent effective stratospheric chlorine (EESC) curve. The long-term changes in the station’s equivalent latitude (indicative of vortex size/position in winter and spring) are derived from MERRA (Modern Era Retrospective-analysis for Research and Applications) reanalyses at ∼ 2 and ∼ 50 hPa. These data are used to attribute some of the upper and middle stratospheric ozone changes to the changes in vortex position relative to the station’s location. In addition, high correlation of the Southern Hemisphere annular mode (SAM) with polar upper stratospheric ozone during years of maximum solar activity points toward a strong relationship between the strength of the Brewer–Dobson circulation and the polar stratospheric ozone recovery. In the lower stratosphere, ozone recovery attributable to CFCs (chlorofluorocarbons) is still not definitive, whereas the recovery of the upper stratosphere is slower than predicted. Further research indicates that dynamical and other chemical changes in the atmosphere are delaying detection of recovery over this station.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Interactive comment on “Long term changes in the upper stratospheric ozone at Syowa, Antarctica” by K. Miyagawa et al

The history of depletion of stratospheric ozone over Antarctica in the austral spring is well known and well documented from the time of the discovery [Farman et al, 1985]. The rapid increase in this depletion during the 1990s [Solomon, 1999] is now being followed by a leveling off of the annual depletion [Salby et al., 2011]. The cause of this depletion again is well known; excess stratosphere...

متن کامل

Four decades of ozonesonde measurements over Antarctica

[1] Ozonesonde observations from Syowa and the South Pole over more than 40 years are described and intercompared. Observations from the two sites reveal remarkable agreement, supporting and extending the understanding gained from either individually. Both sites exhibit extensive Antarctic ozone losses in a relatively narrow altitude range from about 12 to 24 km in October, and the data are con...

متن کامل

Solar cycle variability, ozone, and climate

Results from a global climate model including an interactive parameterization of stratospheric chemistry show how upper stratospheric ozone changes may amplify observed, 11-year solar cycle irradiance changes to affect climate. In the model, circulation changes initially induced in the stratosphere subsequently penetrate into the troposphere, demonstrating the importance of the dynamical coupli...

متن کامل

Subtropical Potential Vorticity Intrusion Drives Increasing Tropospheric Ozone over the Tropical Central Pacific

Drawn from multiple reanalysis datasets, an increasing trend and westward shift in the number of Potential Vorticity intrusion events over the Pacific are evident. The increased frequency can be linked to a long-term trend in upper tropospheric equatorial westerly wind and subtropical jets during boreal winter to spring. These may be resulting from anomalous warming and cooling over the western...

متن کامل

Effects of ozone cooling in the tropical lower stratosphere and upper troposphere

[1] In this paper, we examine the tropical lower stratosphere and upper troposphere and elucidate the key role of ozone changes in driving temperature trends in this region. We use a radiative fixed dynamical heating model to show that the effects of tropical ozone decreases at 70 hPa and lower pressures can lead to significant cooling not only at stratospheric levels, but also in the ‘‘sub-str...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013