Factors influencing the fracture of nickel-titanium rotary instruments.
نویسندگان
چکیده
AIM To evaluate the effect of rotational speed and the angle and radius of curvature of root canals on the fracture of two types of nickel-titanium rotary instruments: K3 and ProTaper. METHODOLOGY A total of 240 root canals of extracted human maxillary and mandibular molars were divided into two groups of 120, according to the angle of the canal curvature (group A: <30 degrees, group B: >30 degrees). Each group was then divided into two subgroups of 60 canals in order to perform instrumentation using K3 and ProTaper rotary instruments at three different rotational speeds: 150, 250 and 350 r.p.m. (20 canals at each rotational speed). Each instrument was used a maximum of 20 times and at one rotational speed only. The angle and radius of canal curvature were measured in the only group in which fractures actually took place (group B). RESULTS There were a total of 22 instrument fractures; all of these occurred in canals with curves >30 degree. In a multivariate analysis, it was demonstrated that the files used at a rotational speed of 350 r.p.m. were more likely to fracture than those used at 250 r.p.m. (OR: 1113.88; 95% CI: 2.36-526420.05) and than those used at 150 r.p.m. (OR: 13531.33; 95% CI: 5.37-34120254.00). A decrease in the angle of curvature of the canal also significantly reduced the likelihood of fracture (OR: 0.2083; 95% CI: 0.068-0.6502). These relationships remained significant after being adjusted for the potential interactions between the remaining variables. No significant differences were found between the files or the radii of the canals. CONCLUSIONS Instrument fracture was associated with rotational speed and the angle of curvature of the canal.
منابع مشابه
A dozen ways to prevent nickel-titanium rotary instrument fracture.
BACKGROUND and Overview. With the increased use of nickel-titanium (NiTi) rotary instruments for root canal preparation in endodontics, instrument fracture has become more prevalent. Extensive research has been conducted on the physical properties and mechanical characteristics of NiTi rotary instruments, as well as the factors that can contribute to instrument failure. NiTi rotary instruments ...
متن کاملTips to avoid instrument separation in endodontics.
procedural accidents and obstacles to normally routine therapy, at almost any stage of treatment. One of these procedural problems is intracanal instrument fracture. Fractured root canal instruments may include endodontic files (Figure 1) and Gates Glidden burs. Instruments are made from nickel titanium (NiTi), stainless steel or carbon steel. Fracture often results from incorrect use or overus...
متن کاملCurrent Strategies in Metallurgical Advances of Rotary NiTi Instruments: A Review
NiTi alloy has been used as the raw material for making endodontic files. The interest in NiTi instrument research has not waned with time. In fact, there is a renewed interest in this field, notably through the application of modern research tools and techniques from other fields, making it a truly cross-disciplinary area of research. In 1988, Walia and colleagues introduced nickeltitanium (Ni...
متن کاملCurrent Strategies in Metallurgical Advances of Rotary NiTi Instruments: A Review
NiTi alloy has been used as the raw material for making endodontic files. The interest in NiTi instrument research has not waned with time. In fact, there is a renewed interest in this field, notably through the application of modern research tools and techniques from other fields, making it a truly cross-disciplinary area of research. In 1988, Walia and colleagues introduced nickeltitanium (Ni...
متن کاملCurrent Strategies in Metallurgical Advances of Rotary NiTi Instruments: A Review
NiTi alloy has been used as the raw material for making endodontic files. The interest in NiTi instrument research has not waned with time. In fact, there is a renewed interest in this field, notably through the application of modern research tools and techniques from other fields, making it a truly cross-disciplinary area of research. In 1988, Walia and colleagues introduced nickeltitanium (Ni...
متن کاملFracture resistance of electropolished rotary nickel-titanium endodontic instruments.
The purpose of this study was to investigate the effect of electropolishing on cyclic flexural fatigue and torsional strength of rotary nickel-titanium endodontic instruments. Electropolished and nonelectropolished ISO size 30 (0.04 taper) EndoWave (J Morita Corporation, Osaka, Japan), ProFile (Dentsply Maillefer, Ballaigues, Switzerland), and RaCe (FKG, La-Chaux De Fonds, Switzerland) instrume...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International endodontic journal
دوره 36 4 شماره
صفحات -
تاریخ انتشار 2003