A Biomechanical and Clinical Comparison of Midshaft Clavicle Plate Fixation: Are 2 Screws as Good as 3 on Each Side of the Fracture?

نویسندگان

  • Christopher G. Larsen
  • Brian Sleasman
  • Steven C. Chudik
چکیده

BACKGROUND The standard of care for plating displaced midshaft clavicle fractures has been 6 cortices of purchase on each side of the fracture. The use of locking plates and screws may afford equivalent biomechanical strength with fewer cortices of purchase on each side of the fracture. PURPOSE To compare the biomechanical and clinical performance of 3- versus 2-screw constructs for plating displaced midshaft clavicle fractures. STUDY DESIGN Controlled laboratory study/cohort study; Level of evidence, 3. METHODS Lateral fragments of simulated midshaft fractures in 10 pairs of cadaveric clavicles were randomly assigned to plate fixation with either 3 nonlocking screws or 2 locking screws. Cyclic tensile loads were applied along the long axis of the clavicle. The constructs were then loaded to failure with pullout forces applied parallel to the long axis of the screws. Additionally, clinical outcomes of patients who had midshaft clavicle fractures that were surgically repaired were retrospectively identified and compared; 21 patients were treated with 3-screw constructs and 20 with 2-screw constructs. RESULTS Biomechanically, there were no significant differences for cyclic displacement, stiffness, yield load, or ultimate load between groups. Forces required for screw pullout were considerably higher than physiologic forces experienced by a healing clavicle in vivo. Clinically, there were no significant differences in American Shoulder and Elbow Surgeons, Constant, visual analog scale, and Single Assessment Numeric Evaluation scores; complications; or mean time to union. Additionally, we found that the plates used in the 2-screw group were consistently shorter. CONCLUSION Plate fixation of displaced midshaft clavicle fractures with 4 cortices of purchase with 2 locking screws demonstrated no significant differences biomechanically when compared with fixation with 6 cortices of purchase and 3 nonlocking screws. Clinically, there were no significant differences in outcomes or complications seen in patients receiving 2- or 3-screw constructs. CLINICAL RELEVANCE Clinical benefits of using the 3-screw construct for plate fixation include decreased surgical exposure, morbidity, and cost, and the use of shorter and noncontoured straight plates eliminates the extra time and technical difficulty associated with matching longer contoured plates to the complex morphology of the clavicle.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Comparison of Results of Treatment of Midshaft Clavicle Fracture between Operative Treatment with Plate and Non-Operative Treatment

Background:  Clavicle fractures are common and usually heal without complications. In this study, we evaluated the outcomes of non-operative versus operative management of displaced fractures.   Methods:  In a prospective clinical trial study, sixty-five patients with displaced clavicle mid-shaft fractures were nonrandomly divided in two treatment groups. The first group underwent non-operative...

متن کامل

A Biomechanical and Clinical Comparison of Midshaft Clavicle Fixation Performed With Either Two Or Three Screws On Each Side Of The Plate

This open-access article is published and distributed under the Creative Commons Attribution NonCommercial No Derivatives License (http://creativecommons.org/licenses/by-nc-nd/3.0/), which permits the noncommercial use, distribution, and reproduction of the article in any medium, provided the original author and source are credited. You may not alter, transform, or build upon this article witho...

متن کامل

Unicortical versus bicortical locked plate fixation in midshaft clavicle fractures.

Higher rates of poor outcomes in displaced midshaft clavicle fractures treated nonoperatively have recently been reported. Along with expanding indications for operative fixation and increasing application of locked plate constructs, it is unknown whether complications related to bicortical penetration of the clavicle can be avoided using unicortical fixation. The purpose of this study is to co...

متن کامل

Use of a real-size 3D-printed model as a preoperative and intraoperative tool for minimally invasive plating of comminuted midshaft clavicle fractures

BACKGROUND Open reduction and plate fixation is the standard operative treatment for displaced midshaft clavicle fracture. However, sometimes it is difficult to achieve anatomic reduction by open reduction technique in cases with comminution. METHODS We describe a novel technique using a real-size three dimensionally (3D)-printed clavicle model as a preoperative and intraoperative tool for mi...

متن کامل

Biomechanical Comparison of Bicortical, Unicortical, and Unicortical Far-Cortex-Abutting Screw Fixations in Plated Comminuted Midshaft Clavicle Fractures.

PURPOSE The objective of this study was to assess the biomechanical properties of bicortical locking screws, unicortical locking screws, and unicortical far-cortex-abutting locking screw fixation in a cadaver model of comminuted midshaft clavicle fractures stabilized with a locking plate placed on the superior surface of the clavicle. METHODS Nine pairs of adult fresh-frozen cadaver clavicles...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2017