Transfemoral aortic valve replacement with the Edwards SAPIEN and Edwards SAPIEN XT prosthesis using exclusively local anesthesia and fluoroscopic guidance: feasibility and 30-day outcomes.

نویسندگان

  • Eric Durand
  • Bogdan Borz
  • Matthieu Godin
  • Christophe Tron
  • Pierre-Yves Litzler
  • Jean-Paul Bessou
  • Karim Bejar
  • Chiara Fraccaro
  • Carlos Sanchez-Giron
  • Jean-Nicolas Dacher
  • Fabrice Bauer
  • Alain Cribier
  • Hélène Eltchaninoff
چکیده

OBJECTIVES The authors report the feasibility and 30-day outcomes of transfemoral aortic valve replacement (TAVR), using the Edwards SAPIEN (Edwards Lifesciences, Irvine, California) and Edwards SAPIEN XT (Edwards Lifesciences) prosthesis, implanted using exclusively local anesthesia and fluoroscopic guidance. BACKGROUND Transfemoral TAVR is often managed with general anesthesia. However, a simplified percutaneous approach using local anesthesia has become more popular because it offers multiple advantages in an elderly and fragile population. METHODS Between May 2006 and January 2011, the authors prospectively evaluated 151 consecutive patients (logistic EuroSCORE: 22.8 ± 11.8%) who underwent TAVR (SAPIEN: n = 78, SAPIEN XT: n = 73) using only local anesthesia and fluoroscopic guidance. The primary endpoint was a combination of all-cause mortality, major stroke, life-threatening bleeding, stage 3 acute kidney injury (AKI), periprocedural myocardial infarction (MI), major vascular complication, and repeat procedure for valve-related dysfunction at 30 days. RESULTS Transarterial femoral approach was surgical in all SAPIEN procedures and percutaneous in 97.3% of SAPIEN XT, using the ProStar vascular closure device, and was well tolerated in all cases. Conversion to general anesthesia was required in 3.3% (SAPIEN cases) and was related to complications. Vasopressors were required in 5.5%. Procedural success was 95.4%. The combined-safety endpoint was reached in 15.9%, including overall mortality (6.6%), major stroke (2.0%), life-threatening bleeding (7.9%), stage 3 AKI (0.7%), periprocedural MI (1.3%), major vascular complication (7.9%), and repeat procedure for valve-related dysfunction (2.0%) at 30 days. A permanent pacemaker was required in 5.3%. CONCLUSIONS This single-center, prospective registry demonstrated the feasibility and safety of a simplified transfemoral TAVR performed using only local anesthesia and fluoroscopic guidance in high surgical risk patients with severe aortic stenosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prospective analysis of 30-day safety and performance of transfemoral transcatheter aortic valve implantation with Edwards SAPIEN XT versus SAPIEN prostheses.

BACKGROUND A new generation of balloon-expandable valves (e.g. Edwards SAPIEN XT) enables the use of a decreased sheath size using the NovaFlex™ delivery system for transfemoral transcatheter aortic valve implantation (TAVI). However, there are few data analysing the efficacy and safety of this new prosthesis. AIMS To evaluate periprocedural and 30-day clinical outcomes using the Edwards SAPI...

متن کامل

Transcutaneous aortic valve replacement with the Edwards SAPIEN XT and Medtronic CoreValve prosthesis under fluoroscopic guidance and local anaesthesia only.

OBJECTIVE To assess the feasibility of transcatheter aortic valve implantation (TAVI; Medtronic CoreValve and Edwards SAPIEN XT) under local anaesthesia with only mild analgesic medication and fluoroscopic guidance. METHODS 461 patients underwent TAVI under local anaesthesia with lidocaine. The procedure was performed successfully in 459 of the cases. All patients were also treated with pirit...

متن کامل

Transcatheter aortic valve implantation: current principles of patient and technique selection and future perspectives.

Surgical aortic valve replacement (AVR) is the conventional treatment for severe aortic stenosis (AS). However, a high operative mortality of 7% to 10% is well recognized in high-risk groups.1,2 Risk of AVR is increased by a number of factors, including increasing age, and comorbidities, such as heart failure, respiratory and renal disease, prior cardiac surgery, and need for concomitant corona...

متن کامل

Contemporary Reviews in Interventional Cardiology Transcatheter Aortic Valve Implantation Current Principles of Patient and Technique Selection and Future Perspectives

Surgical aortic valve replacement (AVR) is the conventional treatment for severe aortic stenosis (AS). However, a high operative mortality of 7% to 10% is well recognized in high-risk groups.1,2 Risk of AVR is increased by a number of factors, including increasing age, and comorbidities, such as heart failure, respiratory and renal disease, prior cardiac surgery, and need for concomitant corona...

متن کامل

Valvular Heart Disease Thirty-Day Results of the SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) Registry A European Registry of Transcatheter Aortic Valve Implantation Using the Edwards SAPIEN Valve

Background—Transcatheter aortic valve implantation was developed to mitigate the mortality and morbidity associated with high-risk traditional aortic valve replacement. The Edwards SAPIEN valve was approved for transcatheter aortic valve implantation transfemoral delivery in the European Union in November 2007 and for transapical delivery in January 2008. Methods and Results—The SAPIEN Aortic B...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JACC. Cardiovascular interventions

دوره 5 5  شماره 

صفحات  -

تاریخ انتشار 2012