New MR imaging methods for metallic implants in the knee: artifact correction and clinical impact.

نویسندگان

  • Christina A Chen
  • Weitian Chen
  • Stuart B Goodman
  • Brian A Hargreaves
  • Kevin M Koch
  • Wenmaio Lu
  • Anja C Brau
  • Christine E Draper
  • Scott L Delp
  • Garry E Gold
چکیده

PURPOSE To evaluate two magnetic resonance imaging (MRI) techniques, slice encoding for metal artifact correction (SEMAC) and multiacquisition variable-resonance image combination (MAVRIC), for their ability to correct for artifacts in postoperative knees with metal. MATERIALS AND METHODS A total of 25 knees were imaged in this study. Fourteen total knee replacements (TKRs) in volunteers were scanned with SEMAC, MAVRIC, and 2D fast spin-echo (FSE) to measure artifact extent and implant rotation. The ability of the sequences to measure implant rotation and dimensions was compared in a TKR knee model. Eleven patients with a variety of metallic hardware were imaged with SEMAC and FSE to compare artifact extent and subsequent patient management was recorded. RESULTS SEMAC and MAVRIC significantly reduced artifact extent compared to FSE (P < 0.0001) and were similar to each other (P = 0.58), allowing accurate measurement of implant dimensions and rotation. The TKRs were properly aligned in the volunteers. Clinical imaging with SEMAC in symptomatic knees significantly reduced artifact (P < 0.05) and showed findings that were on the majority confirmed by subsequent noninvasive or invasive patient studies. CONCLUSION SEMAC and MAVRIC correct for metal artifact, noninvasively providing high-resolution images with superb bone and soft tissue contrast.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Method for Metal Artifact Reduction in CT Scan Images

Introduction In CT imaging, metallic implants inside the tissues cause metal artifact that reduce the quality of image for diagnosis. In order to reduce the effect of this artifact, a new method with more appropriate results has been presented in this research work. Materials and Methods The presented method comprised of following steps: a) image enhancement and metal areas extraction, b) sinog...

متن کامل

Is correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...

متن کامل

Metal artifact reduction strategies for improved attenuation correction in hybrid PET/CT imaging.

Metallic implants are known to generate bright and dark streaking artifacts in x-ray computed tomography (CT) images, which in turn propagate to corresponding functional positron emission tomography (PET) images during the CT-based attenuation correction procedure commonly used on hybrid clinical PET/CT scanners. Therefore, visual artifacts and overestimation and/or underestimation of the trace...

متن کامل

The FSE Cusp Artifact: A Phase Wrap-In Artifact Seen on Routine Clinical MR Images of the Knee

In the course of routine fast spin echo (FSE) magnetic resonance (MR) imaging of knees, we have noticed a distinct and recurrent artifact on MR sagittal knee images. The artifact usually appears as a focal dot of high signal intensity and/or c-shaped ripples at a non-orthogonal angle (Figure 1). The technical features of this artifact have been previously described in an ISMRM abstract in 1995,...

متن کامل

Adaptive Slice Encoding for Metal Artifact Correction

Introduction: Metallic implants can cause moderate or severe distortion artifacts in MR images depending on the shape, size, composition and orientation of the implant. Recentlyproposed methods correct image distortion due to susceptibility shifts near metallic implants by using excitation of limited bandwidths [1] or limited spatial slices [2], both followed by 3D imaging. Here we demonstrate ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of magnetic resonance imaging : JMRI

دوره 33 5  شماره 

صفحات  -

تاریخ انتشار 2011